S42M Hardware User Guide
1VV0301379 Rev. 4
Page
23
of
48
2018-11-28
DC Parameter
6.4.1.
General Purpose I/O (GPIO)
T
amb
= 25°C
Symbol
Item
Condition
Limit
Unit
Min
Typ
Max
V
IL
Input Low Voltage
VSUP = 3,3V
VSUP = 2,8V
-
0
0,9
0,8
V
V
IH
Input High Voltage
VSUP = 3,3V
VSUP = 2,8V
2
1,8
3,3
2,8
3,6
3,1
V
V
OL
Output Low Voltage
VSUP = 3,3V
VSUP = 2,8V
0
-
0,33
0,28
V
V
OH
Output High Voltage
VSUP = 3,3V
VSUP = 2,8V
2,97
2,5
-
3,3
3,1
V
I
OL
/I
OH
Low and High Level
Output Current
A4, F1
VSUP=3.3V
-
20
-
mA
Other Pads
VSUP=3.3V
-
8
-
mA
R
PU
/R
PD
pull-up/down resistor
-
10
-
k
Ω
Table 7: DC Characteristics, Digital IO
6.4.2.
Reset
S42M contains a voltage supervisory circuit that monitors VSUP.
The reset device initiates an internal reset signal whenever:
•
VSUP
drops below V
IT-
or
•
EXT-RES# is
≤V
ILMR
The reset remains active for 200 ms (typical) after:
•
VSUP rises above V
IT-
+ V
hys
and
•
EXT-RES# is
≥V
IHMR
T
amb
= 25°C
Symbol
Item
Limit
Unit
Min
Typ
Max
V
(POR)
VSUP for valid reset function
0,6
V
V
IT-
Negative going Threshold
1,628
1,670
1,695
V
V
hys
Hysteresis
17
mV
V
ILMR
EXT-RES# low-level input voltage
0,3VSUP
V
V
IHMR
EXT-RES# high-level input voltage
0,7VSUP
R
PU
pull-up resistor
10
20
30
k
Ω
Table 8: Reset Characteristics