TELIKOU
TM-200 Eight Channel Main Station
8
When it is used in fixed way, the cross section area of single line should be at least 1.5mm
2
, when it
is used in mobile mode, the cross section area of single line should be at least 0.75mm
2
. When the
cable is longer, the cross section area of cable should be larger. If the cable has more than 2 cores,
it is recommended to use the additional core as common line.
B). Cable connection
The standard TELIKOU intercom cable is connected with a pair of 3-pin XLR connectors, one male
and one female. If longer cable is required, you can connect several cables together with head-end
method.
The wiring of connector is as follows:
Pin 1 --- Common (Shield)
Pin 2 --- Power or Control Signal
Pin 3 --- Audio Signal
Notice:
the pin-1 GND connection for each XLR connector must be insulated from cabinet, and
cannot be connected to shell of XLR connector.
V Troubleshooting
Problem: Power LED wink
Cause 1: Direct short on the intercom channel
Solution 1: Remove all the intercom cables from TM-200. Check each channel one by one, until find
the short channel.
Cause 2: Overload
Solution 2: Decrease the amount of remote stations.
Problem: System feedback (Acoustical)
Cause 1: Listen level control at this station or a remote station is set too high
Solution 1: Adjust
Cause 2: Sidetone null control at this station or a remote station is not adjusted correctly
Solution 2: Adjust. Refer to the procedure in the Front Panel section of this manual.
Cause 3: Channel un-terminated.
Solution 3: Set the TM-200 termination switch to the ON position.
Cause 3: A headset cord is too long or jointing quality.