General aspects: 

Your STD35 can basically be configured in 2 ways: 

 

1. Configuration-Call („easy-setup“)

 

In factory status the STD35 can be configured by a call within the first 3 minutes after connecting to the supply 

voltage. In this case is „logging“ the phone number, from which this call has been made (supposing, that this 

number is transmitted), and will report future event to this phone number.  

You can switch by a call from this phone, from now on known to the STD35, also one of the relays. 

The total STD35 can so be configured by call, in which it is remembering the phone number, for simple 

applications. You don’t need a  PC for it and don’t need to send SMS neither. 

 

2. Configuration via SMS („professional setup“) 

 

For more complexe tasks, e.g. the switching of the 5 outputs, the configuration of several persons being authorized 

to switch or get event messages, the modification of the standard texts and a number of further parameters the  

STD35 via SMS configured and controlled in a very flexible way. 

Even the Reset into the factory status, e.g. to proceed for y new configuration call, is possible. 

The configuration via SMS is described under „SMS commands“. 

Configuration-Call 

Please wait, until the GSM-LED has started to blink. 

Then please call with the mobile phone, which is assigned to control the STD35, the phone number of the SIM card 

being inside of the STD35. The call will be accepted by the STD35 and will be terminated a couple of seconds 

later. As a control sign five signal tones will be sent via DTMF sequences! They can be heard during this call on 

your mobile phone.  

Due to this call the STD35 will be adjusted to the corresponding mobile phone, it will „log“ Your phone number, that 

has been transmitted.  

Therefore please take care, that your mobile phone will transmit the phone number, means the GSM 

function „incognito“ or „private call“ has to be switched off

.  

This is a configuration, that you can settle on your mobile phone, in which you put in the SIM card. (For testing this 

feature you can call another mobile phone, there your phone number or name have to be displayed) 

In case the STD35 e.g. due to being separated from the supply voltage, the STD35 will send, after the reapparition 

of the supply voltage, automatically an SMS with the content „START-UP ALARM“ being sent to the configured 

phone number. 

 

Please consider: When the STD35 is not confirgured in factory status (neither by configurations call nor by 

SMS), it will show this by alternative blinking of the LEDs „Input-Event“ and „Output-Event“. It is switching 

off after 3 minutes autonomously, when not being configured within this time slot. A renewed connecting 

to the power supply will switch on the STD35 anew, and it is expecting again a configuration. 

Usage 

After being configured, the following functions of the STD35 will be at your disposition:  

Switching per call 

Please call, after made configuration, the phone number of the SIM card being inside of the STD35. 

Please take 

care, that your mobile phone is transmitting the phone number

. (see as well „configuration call“). The relay 1 

will then, depending on the configuration, switch for a certain time (factory status: 1 sec). The relays-status-LED 

„Output-Event“ is on during this period. 

Launch an Alarm SMS 

Put for 1 second (Factory configuration) a voltage of 12V at one of the inputs, consider the polarization! Then an 

alarm SMS will be sent to your mobile phone. The LED „input event“ is shortly flashing-up, when you put the 

voltage to the STD35. 

Sending SMS commands 

Your STD35 can launch switching processes as well as be configured via an SMS, that you send to it. 

 

The Format of the Configuration SMS: 

 

To protect your STD35 against not authorized access, each of the configuration SMS to the STD35 has to begin 

with a 4 digit password. The factory default provides the last 4 digits of the IMEI number for it! Your IMEI number is 

visible on the GSM module: 

 

Содержание STD35

Страница 1: ...cording to DIN VDE 0869 and obliged to hand out all necessary documents with the device and to indicate his name and address Devices which are made out of modules have to be considered as an industrial product from the safety perspective During use of the STD35 Short Messages SMS can be generated automatically Costs may occur for you by this SMS traffic Safety Instructions When using products whic...

Страница 2: ...ltage is 250V AC alternating current The maximum switching power per relay is 6A depending on the width of the PCB tracks No special operation position of the device has to be observed When installing the device make sure that the supply cable has a sufficient diameter During operation the temperature has to be between 20 and 55 Celsius In case of condensation allow a period of about 2 hours for a...

Страница 3: ...sed SIM card of a GSM network provider on which the PIN has been put to 0000 To change the PIN accordingly you can use a regular mobile phone Please get the proceeding for Pin change out of the corresponding user manual of your mobile phone In case of using a SIM card with another PIN than 0000 the STD35 will use a wrong PIN during each power on which leads to blocking of the SIM card after the 3r...

Страница 4: ...private call has to be switched off This is a configuration that you can settle on your mobile phone in which you put in the SIM card For testing this feature you can call another mobile phone there your phone number or name have to be displayed In case the STD35 e g due to being separated from the supply voltage the STD35 will send after the reapparition of the supply voltage automatically an SMS...

Страница 5: ...signed mobile phone the relay 1 will switch for a second In case of a SMS O2ON The relay 2 will switch for a second The same is certainly valid as well for the outputs relay 3 to relay 5 In the case that the switching time has been put to 0 number 0 the relays switch permanently to the other status Configuration SMS The configuration SMS is valid only if beginning with the 4 digit password Teh CLI...

Страница 6: ... numbers are entered in international format they have to start with a You can give authorization to up to one hundred of further phone numbers to switch the relay 1 by call To do so you have to build up the extended Clip list respectively you have to enter phone numbers into this Clip list You can also using CD erase again phone numbers within this list The texts for Event respectively Start up m...

Страница 7: ...ol commands O1ON O2OFF O3ON Tracking via GPS By plugging of an appropriate GPS Mouse on the serial connector DSUB 9 of the front side of the STD35 you can transmit the GPS data directly to your mobile phone This function can be launched from the Admin respectively the 4 additional Masters durchgeführt werden The users who are in the extended Cliplist can Not use this function To ask for actual pos...

Страница 8: ...s to be sent to the STD35 2759 BR x x 0 Baudrate 9600 Factory setting x 1 Baudrate 4800 Baud Modem Functionality of the STD35 For using the Modem functionality of the STD35 the serial interface has to be modified using a terminal program The STD35 is put to 9600 Baud 8N1 as the factory setting After connecting the RS232 with a terminal program on the PC just the simple command at has to be sent Th...

Страница 9: ...nd EGSM 900 1800 MHz compatible with ETSI GSM Phase 2 Standard Output power Class 4 2W 900 MHz Class 1 1W 1800 MHz Temperature range 20 C 75 C Weight approx 160g Dimensions 130x85x30 mm LxBxH Supply voltage 5 32V DC Idle current 32 mA peak current up to 500 mA Max Switching current 5 A Max Switching voltage 30V AC Input voltage digital inputs logic 1 5 20V logic 0 1 5V I case of technical problems...