Tamper Switch Installation for TG-7E UL/ULC Commercial Burglary Applications
For all UL/ULC Commercial Burglary Installations, a Tamper switch must be wired to monitor the
TG-7E enclosure. The wiring from Tamper Switch to the panel shall be in a rigid or flexible metal
conduit or be supervised along with other wiring from the TG-7E to the Panel. The tamper switch
does not connect to the TG-7E circuit board.
An easy-attach tamper switch assembly is included with the TG-7E communicator and contains
installation instructions. If a tamper switch is needed for a TG-7FE product, the TG-TAMPER
Accessory can be purchased from most Telguard distributors. Note that a tamper switch is required
when using the TG-7FE in a combination fire and burglary system.