TG-7 Dual Path Series Installation & Operating Guide
6
56052601 Rev B © 2022 Telguard
NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION, OTHER INVOLVED PARTIES
BURGLARY SYSTEM INSTALLATIONS IN CANADA: In order to comply with the requirements in the
Standard for Control Units, Accessories and Receiving Equipment for Intrusion Alarm Systems, ULC-
S304, the communicator must meet these requirements (Security Level I or II):
The TG-7 Dual Path Series communicator must be used in one of the following configurations:
•
Passive communication system line security level P1 (single communication channel) for Security Level I;
or
•
Line security level P2 (multiple communication channels) for Security Level II. There is no heartbeat sent
in this configuration, only periodic test transmissions.
Additionally:
•
Every 24 hours, a test transmission must be sent to the signal receiving centre over each
communication path. Each communication path shall be monitored for integrity (DACT shall have line
monitoring enabled and the communicator shall have both LAN (unless in cellular-only mode) and
cellular connection supervision enabled). For Level A2, the working communication path shall report the
failure of the other channel within 240 seconds.
•
The communicator shall be used in conjunction with a ULC or cUL Listed Control Unit/Alarm Panel.
•
STC1 and STC2 shall be connected from the communicator to the control panel and designated for
general trouble conditions.
•
A tamper switch on the communicator shall be connected directly to an input zone on the control panel,
and the zone shall be designated as the Tamper Protection zone. Tamper wires and all other wires
connecting the communicator to the panel shall be in rigid or flexible metal conduit.
•
The PPF panel presence failure feature must be enabled if the wiring distance between the panel and
the communicator is greater than 18m or in different rooms or the connection is not mechanically
protected in metal conduit; setting is accessible in the online portal.