background image

Circuit Board Configuration Jumpers

To change the jumper settings, remove the top cover.

J6: Call Light Configuration

Jumper on pins 1-2: Light flashes during call
(default-typical setting).

Jumper on pins 2-3: Light stays lit during call.

J8: Relay Configuration

Jumper on pins 1-2: Normal Open (NO) contacts closed
continuously during call (default-typical setting).

Jumper on pins 2-3: Relay contacts toggle at flash rate
during call.

External Switch

Normally, the CIA-1000 indicator light and relay are
actuated by call signals on the intercom channel. The
CIA-1000 may also be modified to actuate the light and
relay using an external, user-supplied switch. See Figure
for location of the switch connector.

Mounting

The CIA-1000 can be wall mounted using the slotted holes
in the bottom of the case.

The front-light version can be installed in an equipment
rack using optional Audiocom rack mounts.

Installation

1.

Plug the supplied PS-L Power Supply into an AC wall
outlet and into the

12-15 VDC

power jack on the

back of the CIA-1000.

2.

Set the

System Select

switch to the "in" position for

Audiocom or the "out" position for RTS TW.

3.

Set the

Channel Select

switch:

• Audiocom, the position of the switch does not

matter.

• RTS TW intercom system: select either channel 1

or channel 2 as desired.

4.

Connect the CIA-1000 to an intercom channel like
any other intercom station.

2

602

Flash during call

On continuously during call

J5: EXTERNAL SWITCH

Toggle during call

On continuously during call

J8: RELAY OPERATION

J6: CALL LIGHT OPERATION

Location of Jumpers and External Switch Connector

RMK-S Single-Unit Rack Mount Kit
for one 1/2-rack wide Audiocom
component*

RMK-D Dual-Unit Rack Mount Kit
for two 1/2-rack wide Audiocom
components*