background image

                                                                                           6

5.

Replace the 

case top

 on the unit.

6.

Adjust the 

hanger switch 

so the button is off the surface of the case top without the handset. 

When the handset is replaced the switch button should be active. This is done by loosening the mounting screws in the hanger and 
moving the switch in or out until you can hear the switch open and close as the handset moves on and off the hanger.

7.

Place the

 handset

 on the hanger.

8.

Plug the 

handset

 into the connector marked HANDSET on the back of the unit.

Handset Mounting Holes

Older 

IP-1616/C-6200 

units require handset

 

mounting holes to be drilled. 

IP-1616/C-6200 Drilling Instructions

To 

drill handset mounting holes into the IP-1616/C-6200 case top

, do the following:

1.

Remove the 

screws

 holding the case top to the unit and position the case top to allow the right side of the case to be drilled.

2.

Go to 

http://www.telex.com/US/dispatch/downloads

, to download the drill template needed from the Drawings section.

3.

Print the drill

 template 

and verify it is to scale. 

NOTE:

 Before drilling, take measures to insure no drill chips and/or debris get into the electronics of the unit.

4.

Overlay the 

template

 on the side of the unit and 

punch center pins

 for each hole to be drilled.

5.

Drill the 

holes

. (3X .313” Dia., 2X .144” Dia.)

6.

Proceed with 

Step 4

 on page 2.

Содержание C-6200

Страница 1: ... black rubber plugs fill the handset mounting holes Older units require mounting holes to be drilled For more information see IP 1616 C 6200 Drilling Instructions if holes are required To remove the unit s case top do the following 1 Remove the screws attaching the top case to the unit 2 With the unit s left side facing forward remove the top and place it to the right back of the unit 3 Remove the...

Страница 2: ...arts are present See Figure 2 NOTE When drilling holes items 9 10 and 12 are used to mount the Hanger Return Spring Item 13 is not used The Washer and Spacer both go on the inside of the case If installing in a case with predrilled holes items 9 10 and 12 are not required FIGURE 2 Option Kit Parts ...

Страница 3: ...e top so the connector is on the inside of the case See Figure 3 FIGURE 3 Inserting Cable through Case Top 6 Solder one lead to pin 1 7 Solder the other lead to pin 3 See Figure 4 NOTE Pin numbers are on the side of the switch FIGURE 4 Lead Placement ...

Страница 4: ...ter it is assembled on the case side After the glue dries verify the screws can be loosened and tightened without the nuts moving before proceeding The speaker may have to be removed to install the hanger return spring 10 Inside the case top assemble the Hanger Return Spring to the standoffs using the 1 4 long screws The spring must be installed so the open slots face away from the keypads and tow...

Страница 5: ...ff 3 Secure the hanger to the standoff with the 5 8 long screws See Figure 7 4 Plug the switch cable connector into the PCBA On the IP 1616 connect to J10 On the C6200 connect to J80 See Figure 8 NOTE The cable may be short which may require partially placing the case top on the unit as the switch cable connector is plugged into the PCBA FIGURE 7 Securing Hanger to the Standoff FIGURE 8 IP 1616 an...

Страница 6: ... require handset mounting holes to be drilled IP 1616 C 6200 Drilling Instructions To drill handset mounting holes into the IP 1616 C 6200 case top do the following 1 Remove the screws holding the case top to the unit and position the case top to allow the right side of the case to be drilled 2 Go to http www telex com US dispatch downloads to download the drill template needed from the Drawings s...