Installation
18
FIGURE 12.
Using the termination plugs supplied with the ES4000A for mixed wet- and dry-line operation.
In this
example, channels 5 and 6 are powered from a PS2000L Power Supply (wet lines), while channels 3 and 4 are operated
without power (dry lines). Any remote station connected to channel 3 or 4 must supply its own power. For example, a
US2000A that is powered by a PS-L Power Supply could be connected to channels 3 and 4. The advantage of dry-line
operation is that intercom stations may be operated over a much greater distance.
XP-ES4000
12-15 VDC
+
-
3
SPEAKERS
PROGRAM
INPUTS
4
LINE LEVEL
1 VRMS
EXP
OUT
CAN 3-6 OUTPUTS
EXP
IN
5
6
3
4
5
6
PGM VOLUME
BAL-OUT
UNBAL-IN
Telex
®
FRONT
BACK
CH 3-6
ES4000A
PUSH
PUSH
PUSH
PUSH
PS2000L Power Supplies
Combine / Isolate Switches
set to Combine
CHN 1
CHN 2
CLASS 2 WIRING 1.5A 24VDC
100-249 VAC 60/50 HZ
MADE IN USA
®
CHN 1
CHN 2
CLASS 2 WIRING 1.5A 24VDC
100-249 VAC 60/50 HZ
MADE IN USA
®
CH 6
CH 5
TO US2000A
EXP IN CONNECTOR
TO THE EXP IN CONNECTOR
OF ANOTHER ES4000A
CH 6
CH 5
1
1
1
1
1
CH 6
CH 5
CH 3
CH 4
TERMINATION
PLUGS
DRY LINES TO REMOTE STATIONS
ON CHANNELS 3 AND 4
1
1
WET LINES TO 1/2 OF REMOTE
MASTER STATIONS OR BELT PACKS ON
CHANNELS 5 AND 6
WET LINES TO 1/2 OF REMOTE
MASTER STATIONS OR BELT PACKS ON
CHANNELS 5 AND 6
1
11
5
5
NOTE
: For further
information about
cable numbers, see
“Cables” on
page 20