background image

11

Connection Notes

Connection Notes

Typical connections for the US2000A, ES4000A and various power supplies are shown starting with Figure 6. Select the 
configuration which most closely matches your intended usage.

The US2000A and ES4000A normally draw operating power from the intercom channel power supplies (SPS2000A, 
PS2000L, etc.). Alternatively, you can use option PS-L Wall-pack Power Supplies. If you are using PS-L Wall-packs, 
connect them to the 12-15 VDC jacks on the back panels of the US2000A and ES4000A. When PS-L Wall-packs are used, 
the US2000A / ES4000A will not draw power from the intercom channel power supplies, leaving more power for belt 
packs.

IMPORTANT

: The PS-L power supply only provides power for the station that it is connected to. You cannot use the PS-L to 

power the intercom channels!

Never connect more than 1 SPS2000A, PS2000L, or PS4000 Power Supply to the same intercom channel. This will cause 
poor audio quality and increased noise. Typically, all power supplies are located at a central location, such as a central 
master station. This lets the central master station operator turn off the intercom system when it is not being used.

Termination Plugs: The ES4000A is supplied with 2 termination plugs for special applications where 1 or more channels 
are unpowered. Figure 12 on page 18 and Figure 13 on page 19 show example of how to use these plugs. If all of your 
incoming channels will be powered from an SPS2000A, PS2000L, or PS4000 power supply, the termination plugs are not 
needed.

Содержание Audiocom ES4000A

Страница 1: ...Talk Listen Call Talk Listen Call Talk Listen Call Talk Listen Call 3 4 5 6 ES4000A ES4000A Intercom Expansion Station User Instructions 9350 7551 000 Rev C 04 2006...

Страница 2: ...made via UPS Ground prepaid you may request from Factory Service a different shipment method Any shipment upgrades will be paid by the customer The equipment should be shipped in the original packing...

Страница 3: ...5 Audiocom Call Send and Receive DIP Switches 7 Balanced Unbalance Switch SW2 7 Direct Program Listen Enable Disable Jumpers 7 Sidetone Trimmers 7 Mounting Configurations 7 Connection Notes 11 Cables...

Страница 4: ......

Страница 5: ...eaker outputs for independent monitoring of one or more of the 4 channels if desired The US2000A ES4000A combination can be used as a simple multi channel intercom user station In this configuration t...

Страница 6: ...uirements and call signaling requirements 8 Program Inputs Connector and Trimmers Each intercom channel has its own program input and level adjustment trimmer For each program input there is an intern...

Страница 7: ...d 3 screws from each side DIP Switches DIP switches and their default settings are listed in Table 1 on page 6 The following paragraphs provide additional details Program Interrupt DIP Switches Each I...

Страница 8: ...io Call Send Ch 3a ON Closed Enabled OFF Open Disable ON SW1 7 Audio Call Send Ch 4a ON Closed Enabled OFF Open Disable ON SW1 8 Audio Call Send Ch 4a ON Closed Enabled OFF Open Disable ON Push button...

Страница 9: ...jack on the back of the ES4000A To disable direct program listening for a program input reset the appropriate jumper as show in Table 2 Locations of the jumpers are shown in Figure 2 on page 4 Sideto...

Страница 10: ...rack wide components SPK 1000 RMK S Single Unit Rack Mount Kit for one 1 2 rack wide Audiocom component RMK D Dual Unit Rack Mount Kit for two 1 2 rack wide Audiocom components RMK M Multi Unit Rack M...

Страница 11: ...an ES4000A Connections and further details for this configuration are shown in Figure 6 NOTE An additional rack mount space is shown between the two PS4000 power supplies This may be required to prev...

Страница 12: ...re 6 The power supply connections for the US2000A are shown in Figure 7 the power supply connections for the ES40000A are shown in Figure NOTE Additional rack spaces are shown between the rows of powe...

Страница 13: ...cks IMPORTANT The PS L power supply only provides power for the station that it is connected to You cannot use the PS L to power the intercom channels Never connect more than 1 SPS2000A PS2000L or PS4...

Страница 14: ...NECT TO ES 4000 CLASS 2 WIRING 2A 24VDC CH 7 10 PS4000 ES4000A 12 15 VDC 3 SPEAKERS PROGRAM INPUTS 4 LINE LEVEL 1 VRMS EXP OUT CAN 3 6 OUTPUTS EXP IN 5 6 3 4 5 6 PGM VOLUME BAL OUT UNBAL IN Telex CHN...

Страница 15: ...HZ MADE IN USA PS2000L Channel 2 Power Combine Isolate Switch set to Combine CHN 1 CHN 2 100 240 VAC 60 50 HZ MADE IN USA INPUT 1 SPEAKER INPUT 2 LINE LEVEL 1 VRMS 12 15 VDC 1 SPEAKERS PROGRAM INPUTS...

Страница 16: ...24VDC 100 249 VAC 60 50 HZ MADE IN USA CHN 1 CHN 2 CLASS 2 WIRING 1 5A 24VDC 100 249 VAC 60 50 HZ MADE IN USA XP ES4000 12 15 VDC 3 SPEAKERS PROGRAM INPUTS 4 LINE LEVEL 1 VRMS EXP OUT CAN 3 6 OUTPUTS...

Страница 17: ...FRONT BACK CH 3 6 ES4000A PUSH PUSH PUSH PUSH PS2000L Power Supplies Combine Isolate Switches set to Combine CHN 1 CHN 2 CLASS 2 WIRING 1 5A 24VDC 100 249 VAC 60 50 HZ MADE IN USA CHN 1 CHN 2 CLASS 2...

Страница 18: ...OUTPUTS EXP IN 5 6 3 4 5 6 PGM VOLUME BAL OUT UNBAL IN Telex FRONT BACK CH 3 6 ES4000A PUSH PUSH PUSH PUSH CHN 1 CHN 2 CLASS 2 WIRING 1 5A 24VDC 100 249 VAC 60 50 HZ MADE IN USA CHN 1 CHN 2 CLASS 2 WI...

Страница 19: ...KERS PROGRAM INPUTS 4 LINE LEVEL 1 VRMS EXP OUT CAN 3 6 OUTPUTS EXP IN 5 6 3 4 5 6 PGM VOLUME BAL OUT UNBAL IN Telex FRONT BACK PUSH PUSH PUSH PUSH FROM MASTER STATION OR BELT PACK FROM MASTER STATION...

Страница 20: ...NPUTS 4 LINE LEVEL 1 VRMS EXP OUT CAN 3 6 OUTPUTS EXP IN 5 6 3 4 5 6 PGM VOLUME BAL OUT UNBAL IN Telex FRONT BACK CH 3 6 ES4000A PUSH PUSH PUSH PUSH PS2000L Power Supplies Combine Isolate Switches set...

Страница 21: ...LINE LEVEL 1 VRMS EXP OUT CAN 3 6 OUTPUTS EXP IN 5 6 3 4 5 6 PGM VOLUME BAL OUT UNBAL IN Telex FRONT BACK CH 3 6 ES4000A PUSH PUSH PUSH PUSH CH 1 CH 2 CH 6 CH 5 CH 4 CH 3 INPUT1 INPUT2 12 15 VDC BAL 1...

Страница 22: ...aker cable with RCA plugs One supplied with each SPS2000A SPK 1000 and SPK 2000 5 18 457mm CHANNEL OUTPUT cable stereo miniplug to stereo miniplug One supplied with each ES4000A 6 18 457mm CHANNEL OUT...

Страница 23: ...itchcraft Pin 1 Common Pin 2 Shield Standard cables are generally constructed using a male connector at one end and a female connector at the other end This allows several cables to be interconnected...

Страница 24: ...Installation 22...

Страница 25: ...tment procedure as described in the US2000A User Instructions except substitute channel 3 channel 4 etc The locations of the ES4000A sidetone trimmers are shown in Figure 15 Operation The ES4000A chan...

Страница 26: ...L switch set to BAL position Output Level 1VRMS nominal Input Impedance 300 ohms Bridging Impedance greater than 10 000 ohms Sidetone 40dB 35dB adjustable range Call Signalling Send 20kHz 100Hz 0 47VR...

Страница 27: ...EL 3 6 OUTPUTS Connector Connector Type DB15F Female 15 pin D sub Pin 1 Channel 3 intercom audio input output high Pin 2 Channel 3 intercom audio input output low Pin 3 Common Pin 4 Channel 5 intercom...

Страница 28: ...b One supplied with each ES4000A Pages 16 21 All cables labeled with number 6 should be labeled with number 11 The description for cable number is 11 is 18 457mm CHANNEL OUTPUT cable 15 pin Male Dsub...