14.

 

Grounding or Polarization 

Do not defeat the safety purpose of the polarized or ground-type plug. A polarized plug has two blades with one 
wider than the other. A grounding type plug has two blades and a third grounding prong. The wider blade or the 
third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician 
for replacement of the obsolete outlet.  
 

15.

 

Power-Cord Protection 

Power-supply cords should be routed to that they are not likely to be walked on or pinched by items placed upon 
or against them, paying particular attention to cords at plug, convenience receptacles, and the point where they 
exit from the product. 

16.

 

Lightning 

For added protection for this product during a lightning storm, or when it is left unattended and unused for long 
periods of time, unplug it from the wall outlet. This will prevent damage to the product due to lightning and 
power-line surges. 

Not applicable when special functions are to be maintained, such as evacuation systems 

17.

 

Overloading 

Do not overload wall outlets, extension cords or integral convenience receptacles as this can result in a risk of fire 
or electric shock. 

18.

 

Object and Liquid Entry 

Never push objects of any kind into this product through openings as they may touch dangerous voltage points or 
short-out parts that could result in a fire or electric shock. Never spill liquid of any kind on the product. 

19.

 

Inflammable and Explosive Substance 

Avoid using this product where there are gases, and also where there are inflammable and explosive substances 
in the immediate vicinity. 

20.

 

Heavy Shock or Vibration 

When carrying this product around, do not subject the product to heavy shock or vibration. 

21.

 

Servicing 

Do not attempt to service this product yourself as opening or removing covers may expose you to dangerous 
voltage or other hazards. Refer all servicing to qualified service personnel. 

22.

 

Damage Requiring Service 

Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following 
conditions: 

a.

 

When the power-supply cord or plug is damaged. 

b.

 

If liquid has been spilled, or objects have fallen into the product. 

c.

 

If the product has been exposed to rain or water. 

d.

 

If the product does not operate normally by following the operating instructions. Adjust only those 
controls that are covered by the operating instructions as an improper adjustment of other controls 
may result in damage and will often require extensive work by a qualified technician to restore the 
product to its normal operation. 

e.

 

If the product has been dropped or damaged in any way. 

Содержание Confidea CD G3

Страница 1: ...confidea System Description...

Страница 2: ...Attention This manual for Wireless Confidea System 3 0 is valid only for all WCAP firmware version 1 06 WCAP fpga version 1 06 WDU firmware version 1 06 WCAP 71 98 0033 Cocon 3 02...

Страница 3: ...Conformity and Certification info for Japan 6 3 3 Important safety instructions 6 3 4 General conformity info 10 3 5 Power Connections 10 4 Confidea wireless system information 10 4 1 General system a...

Страница 4: ...anual have made every effort in the preparation of this book to ensure the accuracy of the information However the information in this manual is supplied without warranty either express or implied Nei...

Страница 5: ...he FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy...

Страница 6: ...the product is operated 2 Retain Instructions Radiofrequency radiation exposure Information This Wireless discussion units and the Wireless Access Point comply with FCC radiation exposure limits set...

Страница 7: ...y tub in a wet basement or near a swimming pool in an unprotected outdoor installation and the like 10 Accessories Only use attachments accessories specified by the manufacturer Do not place this prod...

Страница 8: ...bjects of any kind into this product through openings as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock Never spill liquid of any kind on the...

Страница 9: ...completion of any service or repairs to this product ask the service technician to perform safety checks to determine that the product is in proper operating condition 25 Coax Grounding If an outside...

Страница 10: ...closure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation mark within an equilateral triangle is intended to alert the user to the presence of impor...

Страница 11: ...called WCAP G3 This Access Point has a powerful built in web server that allows configuring and monitoring of the system from any PC or mobile device through a standard internet browser 4 1 2 Standalo...

Страница 12: ...Institute of Electrical and Electronics Engineers in order to insure inter operability between different WLAN vendors 802 11 Standard Release Date Frequency GHz Maximum bit rate Mbits sec Modulation...

Страница 13: ...also ensure a guaranteed quality of service for the audio streams on the wireless network 5 2 1 Frequency bands The Confidea wireless system supports the following frequency bands ISM 2 4 GHz RLAN low...

Страница 14: ...V V V 2437 MHz V V V V 2442 MHz V V V V 2447 MHz V V V V 2452 MHz V V V V 2457 MHz V V V V 2462 MHz V V V V 2467MHz V X V V 2472 MHz V X V V In the RLAN low frequency band there are 8 non overlapping...

Страница 15: ...Hz V V V V 5540 MHz V V V V 5560 MHz V V V V 5580 MHz V V V V 5600 MHz V X V V 5620 MHz V X V V 5640 MHz V X V V 5660 MHz V V V X 5680 MHz V V V X 5700 MHz V V V X In the 5 GHz ISM frequency band ther...

Страница 16: ...1 Introduction 23 7 2 Electrical and acoustic properties 23 7 3 Microphone connector 23 7 4 Operation 23 8 Battery pack 25 8 1 Introduction 25 8 2 Controls and indicators 25 8 3 Installation 27 9 Wir...

Страница 17: ...the volume level of the headphones 6 Microphone status LEDs Indication LEDs show the status of the microphone Red active green request 7 PRIOR button Chairman Unit Long press temporarily deactivates t...

Страница 18: ...18 15 Battery status LEDs Red LED blinking the remaining operation time 1 Hz 4h remaining 2Hz 2h remaining 4Hz 1h remaining Note Units with the out of range LED on will be switched off after 2 minutes...

Страница 19: ...6 Wireless contribution units 19 Confidea DD G3 Confidea CD G3...

Страница 20: ...20 Confidea DV Confidea CV...

Страница 21: ...6 Wireless contribution units 21 Confidea Back...

Страница 22: ...oments until the LEDs are blinking When units are connected to WCAP and the WCAP is switched off the units will go to sleep mode after _ 2 min if no connection with another WCAP could be established I...

Страница 23: ...perties 7 3 Microphone connector pin 1 microphone GND pin 2 microphone signal pin 3 unused pin 4 LED pin 5 LED 7 4 Operation The microphone contains the following elements Transducer type Back electre...

Страница 24: ...lug connects the microphone to the unit The colour of the microphone indicator ring shows the status of the microphone Color Condition Red on Microphone active Red flash Last minute of speech time if...

Страница 25: ...8 1 Introduction The Confidea wireless battery pack is used with the wireless conference units Output voltage 7 2V Capacity 6600 mAh Charge time 4 Hours Max charge voltage 15V Charge current 2 A Auto...

Страница 26: ...in the wireless unit 4 Power LED indicates that the charger is connected and powered 5 Charging LED Indicates the charging status in progress or completed when the wall plug battery charger is connect...

Страница 27: ...he charge the higher the number of LEDs that light up LED on Remaining charge LED 1 red 0 20 LED 2 orange 20 40 LED 3 orange 40 60 LED 4 green 60 80 LED 5 green 80 100 After the display of the battery...

Страница 28: ...he WCAP 9 2 Installation 9 2 1 Wall Mounting The WCAP can be mounted on the wall by means of the 2 fixing holes at the bottom side of the device To prevent accident this device must be securely attach...

Страница 29: ...is done through RJ45 connectors at the back of the WCAP 4 Cable retention clip The cable retention clip is used to safeguard the cable of the power adaptor 5 LAN port Through the LAN connector at the...

Страница 30: ...ixed green Connected with uniCOS Blinking red Connection error Blinking green Connecting with uniCOS Off Standalone Blinking white Update in progress Red Transmission error Retransmit Green Packet tra...

Отзывы: