5.1.d  Identifiers menu

Since  the  output  transport  stream  is  formed 

from  three  inputs,  it  is  necessary  to  specify  the 

identifiers of it.
In this menu the user specifies the desired values 

for: 

transport_stream_id  (ts_id);  network_id  (n_id) 

and original_network_id (on_id)

.

 5.1.e  Services menu

This  menu  shows  the  list  of  transport  stream 

services at the input. Each time the user selects a 

new  input  transport  stream,  the  unit  performs  a 

search for services.
During the process, the unit will show the message 

below displaying the number of channels as soon 

as they are being found:

Once the search has completed, it is displayed a list 

of services. Each service is part of a list containing 

all  services  found  in  the  3  input  channels.  The 

information available in this screen is the following:

 

 

• 

Identifier  of  the  input

  to  which  the  service 

belongs: A, B or C.

• 

Status  of  the  encryption  of  the  service

,  for 

both  input  and  output  of  the  module.  When 

the  service  is  set  to  ON/OFF,  only  is  displayed 

the input status. When the service is configured 

as DCY, it is displayed its status before and after 

passing through the CAM. 

Additionally,  on  the  upper  right  corner  of  the 

window it is indicated the status of the service on 

the  input  (encoded  or  plain),  for  those  services 

set to ON and DCY:

  

Scrambled service in the input: a)  if set to 

OFF, it does not pass to the output; b) if 

set to ON, it exits without going through 

the CAM.

 

Free service in the input: a)  if set to OFF, 

it does not pass to the output; b) if set to 

ON,  it  exits  without  going  through  the 

CAM.

      Free service in the input, and free service 

in the output (configured as DCY).

      Scrambled service in the input, and free 

service in the output (configured as DCY).

      Scrambled  service  in  the  input,  and 

scrambled  service  in  the  output 

(configured as DCY).

• 

Service’s order 

within the list, and total number 

of  services  found  from  all  inputs  (see  figure, 

where 7/56 indicates that it is the index 7 of a list 

containing 56 services).

• 

Statistics

.  A  value  indicating  the  occupation 

of  this  service  at  the  output  as  well  as  the 

percentage that remains free.

It is displayed as N/M (23/50 in the figure), where:

 

»

indicates the capacity needed at the output 

to  transport  this  service.  If  this  service  is  ON, 

it  indicates  the  percentage  of  the  output 

occupied by the service, this is, percentage of 

the whole bit rate occupied by this service if it 

is enabled to pass through.

 

»

M

 indicates the percentage of the output that 

still  remains  available  to  transport  additional 

services. This  value  is  updated  if  you  change 

the  status  of  a  service  (when  switching  to 

ON,  the  output’s  occupation  is  subtracted 

automatically  -  switching  to  OFF  it  is  added) 

thus  giving  a  good  estimate  of  available 

capacity before saving the configuration. It is 

said an estimate because its value is increased 

or decreased according to what would occupy 

the  complete  service  (without  considering 

PID filtering, even when selected previously). 

Once  saved  the  configuration,  this  value  will 

Содержание MUX DVBS2-COFDM CI

Страница 1: ...MUX DVBS2 QAM CI MUX DVBS2 COFDM CI EN Refs 564101 564201 User manual w w w t e l e v e s c o m ...

Страница 2: ......

Страница 3: ...ments description 11 4 1 Introduction 11 4 2 Power Supply Unit 12 4 3 Amplifiers 13 4 4 Programming Unit 14 5 Instructions for use 15 5 1 Standard menu 15 5 2 Extended menu 20 5 3 Saving parameters 24 6 Device control 24 7 Example installation 26 8 Rack mount standards 27 9 Standards for wall mounting cabinets 29 MUX DVBS2 QAM COFDM CI ...

Страница 4: ......

Страница 5: ...4101 Modulation format QAM 16 32 64 128 256 Scrambling DVB ET300429 Symbol rate Mbaud 6 9 Interleaving DVB ET300429 Roll off factor 15 Bandwidth max MHz 8 3 Block code Reed Solomon 188 204 Spectral inversion selectable Normal Inverted OFDM modulator Ref 564201 Modulation format QPSK 16QAM 64QAM Scrambling DVB ET300744 Guard interval 1 4 1 8 1 16 1 32 Interleaving DVB ET300744 FEC 1 2 2 3 3 4 5 6 7...

Страница 6: ... For higher temperatures forced ventilation will be used 1 2 Broadband amplifier technical specifications 1 Forward path 2 Return path active passive Amplifier Ref 5575 Frequency range MHz 46 862 Connector tipo F female Gain dB 44 2 5 Powering V 24 Regulation margin dB 20 Consumption 24 Vdc mA 450 Output level 60 dB dBµV 105 42 CH CENELEC Test socket attenuation dB 30 Amplifier Ref 451202 Frequenc...

Страница 7: ...ly Unit technical specifications 1 4 Block diagram PSU Ref 5629 Mains voltage frequency V Hz 196 264 50 60 Total maximum current OUT1 OUT2 A 5 24V Output voltage V 24 Maximum current per output 4 24V Ref 564101 Ref 564201 ...

Страница 8: ... 5629 T 0X Power Supply Unit 24VDC 5A Accessories 7234 Programming Unit 5071 T03 T05 T 0X Wall mounting rail L 50 cm 5239 T03 T05 T 0X wall mount rail 12 units PSU L 56 cm 5301 19 inch sub rack frame 507202 T 0X Lockable cabinet with Ventilation Unit 7 Modules PSU 4061 75 Ohm DC Block terminal load 4058 75 Ohm terminal load 422601 T05 to T 0X Power interconnection lead L 40 cm 422602 T05 to T 0X M...

Страница 9: ...tallation 3 1 Wall mount 7234 NOTE The use of both PSU power outputs is recommended to balance the consumption For example 4 3 or 3 4 5575 4061 5071 5239 564101 564201 5629 SAT IF INPUT OUTPUT QAM 564101 COFDM 564201 ...

Страница 10: ...MUX DVBS2_QAM COFDM CI 10 3 2 19 inch rack mount 5301 ...

Страница 11: ...s modulated either in QAM format Ref 564101 or COFDM To configure the multiplexer operating parameters input frequency output channel modulation format and adaptation of services mainly can be used the universal programming unit ref 7234 or the TSuite software 4 Elements description 4 1 DVBS2 QAM CI 564101 DVBS2 COFDM CI 564201 1 SAT IF input 2 SAT IF input output 3 RF input 4 RF output 5 Powering...

Страница 12: ... increases about an average of 70 mA since CAM consumptions in the market can vary between 20 100 mA Each LNB feed activated increases the multiplexer consumption about 250 mA also depending on the LNB model The two PSU power outputs must be used in order to balance their consumptions in a chassis therefore whenever the demand of power exceeds 4A max current for each output it is necessary to dist...

Страница 13: ...features a test socket 30 dB as well as the RF output connector As the rest of T 0X units this amplifier is powered via the 24 Vdc power BUS Broadband amplifier in shielded zamak chassis with gain configured by the installer 1 RF output 2 Test output 3 RF input 1 4 RF input 2 1 Mains input 196 64 V 50 60 Hz 2 Ground terminal 3 ON OFF LED 4 MATV input Return channel output 5 MATV input test 6 MATV ...

Страница 14: ...Selection of parameter positioning of the cursor Modification of the parameter chosen by the cursor flashing short press Change menu long press Change between Principal and Extended menus long press Save changes to memory Cloning menu Increases the contrast of the screen Decreases the contrast of the screen ...

Страница 15: ...y values is 950 2150 MHz whereas the range for symbol rate is 10 to 30 Mbaud for DVB S2 signals and 2 to 42 5 Mbaud for DVB S signals Detection of both DVB S2 5 Instructions for use Connect the programming unit to the front socket of the module PRGM At first the controller s firmware version will appear Next it is displayed the firmware version of the corresponding module and DVB S signals is auto...

Страница 16: ...ows to select Cell id parameter cell identifier of the COFDM modulation Normal Inverted mode of the COFDM output Note The bandwidth required depends on the number of services present on the output those selected as ON or DCY see menu of services 5 1 c Output menu Next main menu shows the output frequency channel the output level control and the output mode selection To change a parameter press the...

Страница 17: ...hout going through the CAM Free service in the input a if set to OFF it does not pass to the output b if set to ON it exits without going through the CAM Free service in the input and free service in the output configured as DCY Scrambled service in the input and free service in the output configured as DCY Scrambled service in the input and scrambled service in the output configured as DCY Servic...

Страница 18: ...ist If any input is not available the screen will display Unlock when trying to access its list of services Within the service menu you can get access to the advanced PID menu by a long press on key more than 2 sec This option shows the list of PID belonging to the service that was displayed on the standard menu Be aware that it should be used carefully and may need to know the characteristics of ...

Страница 19: ...uests unscrambling to the CAM module if available 5 1 f Measure menu 1 This menu provides an indication of the input signal quality by estimating both C N dB and Link margin dB 5 1 g Measure menu 2 This menu shows messages related to adaptation and deleting of services configured in the SERVICES menu If all input are unlocked no message is displayed Possible messages to be displayed are the follow...

Страница 20: ... menu for Ref 564201 allows selecting the following parameters Dir CDC Address of the device that allows selecting it via a control BUS connected to the Headend Control Module CDC With this menu you can change the address of the unit on the remote control bus when the unit is connected to a headend control module via its communications BUS It is the responsibility of the user to ensure that each 5...

Страница 21: ... KHz tone Symbol on the RCU screen means 22 KHz If you choose option 0 volts for the LNB it disables any satellite selection 5 2 c Temperature measurement menu This menu shows the current measured temperature and the peak in º C The maximum recorded temperature may also be reset by press and holding the more than 3 sec 5 2 b Configuration menu 2 This menu allows to select the number of unit inputs...

Страница 22: ...re the same conditional access system and the CAM was able to support the modulated output baud rate DCY SAFE There are 2 possible status ON enabled and OFF disabled This choice configures the behavior of the module to face changes in the input transport stream Professional CAMs can process a given maximum number of PIDs to be decoded at the same time and therefore the multiplexer has to be config...

Страница 23: ...ght of the value to indicate the user to assign a different value 5 2 h Service_ids remapping menu This menu allows configuring the output service_id value for each one of the services configured to ON DCY Using this option you can change a service by another previously OFF and keep the same service_id allowing a large number of receivers automatically detect the change without having the need to ...

Страница 24: ...and 254 5 3 Saving parameters After setting up the unit by means of the two menus available main and extended all data will be saved by pressing the button for about 3 seconds The display shows Do not remove the programmer before the message disappears from the screen If configuration data are changed but not saved previous settings will be restored after about 30 seconds Therefore all changes mad...

Страница 25: ...25 Flow diagram of menus Main menu Extended menu Long press Ref 564101 Ref 564101 Ref 564201 Ref 564201 ...

Страница 26: ...MUX DVBS2_QAM COFDM CI 26 7 Example installation The illustration shows an installation to distribute 20 channels of MUX DVBS2_QAM COFDM CI T 0X ...

Страница 27: ...th the MUX DVBS2_QAM COFDM CIT 0X is located in warm places with tem peratures higher than 45 C These ventilators will be installed on a tray that is fixed inside the cabinet fig 1 2 This way the ventilators will force the fresh air entering from the base of the cabinet to circulate between the modules and be expelled through a gap on top of the cabinet 3 5 cm approx See fig 3 8 Norms for rack mou...

Страница 28: ...is is to facilitate the ventilation of the units fig 5 It is very important that this process operates co rrectly therefore the following must be observed Do not open the side doors as this would cause the ventilators to extract the air from the outside rather than the air inside the rack Do not place objects close to the rack that may block the entry and exit openings for the air If the rack is n...

Страница 29: ...acement horizontal or vertical way IMPORTANT The scheme of recommended ventilation is the one in the figure in any case of cabinet placement horizontal or vertical EXTRACTOR for forced ventilation must be onto the highest module Horizontal placement Vertical placement Lower grid in any wall Maximum environment temperature 45ºC ...

Страница 30: ... the cabinets is strongly recommended hanging them as near to the floor as possible If the horizontal placement is impossible then vertical placement is allowed Respect the recommended minimum distances in the attached schemes Install the cabinet as low as possible Maximum T 45ºC ...

Страница 31: ...31 ...

Страница 32: ... that is in force at the time of purchase is applied Keep the purchase invoice to determine this date During the guarantee period Televés S A complies with the guarantee by repairing or substituting the faulty equipment The harm produced by improper usage wear and tear manipulation by a third party catastrophes or any other cause beyond the control of Televés S A is not included in the guarantee ...

Страница 33: ...EN 33 ...

Страница 34: ...MUX DVBS2_QAM COFDM CI 34 ...

Страница 35: ...EN 35 ...

Страница 36: ...564101 564201_000_EN ...

Отзывы: