background image

EN

25

24

Error Messages

LOW BATTERY

Indicates that the battery is about to finish. The 

battery icon is red now. It is recommended to con-

nect the meter to the external power source.

LOW BATTERY

Shutting down

Some time after the LOW BATTERY message 

appears (time varies depending on the functions 

used), it will appear this message. If the meter is 

not connected to the external power source, it will 

switch off.

BAD POWER

Unplug power source

This message appears when the meter is con-

nected to an external power source that does 

not supply it the right power. Please, use only the 

power source provided with the 

H30FLEX

.

SHORT-CIRCUIT

Check installation

This message appears when the meter detects a 

short-circuit at the RF input. It is recommended to 

check the installation to find out why the short-

circuit is produced.

DC OUTPUT LIMIT EXCEED

Switch DC OUTPUT off

This message appears when the meter detects 

an excessive consumption from the device that is 

being powered. It is recommended to turn off the 

powering feature of the 

H30FLEX.

DC AT RF INPUT

Check installation

This message appears when the meter detects 

DC at the RF input that is not generated by the 

H30FLEX

. It is recommended to check the instal-

lation.

Maintenance

Always disconnect the unit before cleaning. Use 

only a mild solution of detergent and water applied 

with a soft damp cloth. Dry thoroughly before use.
Do not use aromatic hydrocarbons or chlorinated 

solvents. These products may damage the unit.
Do not use alcohol or alcohol based products 

on the front panel, especially the display. These 

products may damage the unit.

Содержание 593301

Страница 1: ...Digital processing handheld DVB Meter Analyzer EN Refs 593301 593302 593303 593304 593360 593361 Instruction Manual w w w t e l e v e s c o m ...

Страница 2: ......

Страница 3: ...ols 8 Keyboard 8 Power supply 9 About battery 9 Before starting 11 Product operation 11 1 Channel Info 11 2 Spectrum 12 3 MPEG 13 4 System Scan 14 5 Satellite Test 15 7 Constellation 16 8 Echoes 17 9 Camera 18 10 Setup 19 Driver Installation only for old hardware version with USB connector 19 Web Application 20 1 Measurements 21 2 Plans 21 3 SCR 23 4 Quality Profiles 23 5 Clone 23 6 Update 24 Erro...

Страница 4: ...personnel Follow the instructions in this manual when replacing the battery Heat The product should be situated away from heat sources such as radiators heat registers stoves or other products that produce heat Do not place naked flame sources on the meter such as lighted candles Maximum current consumed by the meter 2A Battery Battery must be replaced by qualified personnel following the steps me...

Страница 5: ...surements needed in today s fulfilment environment Key Features User friendly handheld DVB meter Complete portfolio of Analog Digital measurements with easy to read pass fail indicators Quick and easy to use interface with features such as Channel measurements System Scans Constellation Diagram Spectrum Analyzer Echoes Datalogger and more Rugged light weight fully automatic fast and accurate Easy ...

Страница 6: ...Output 12VDC 2A Battery LiIon smart battery 7 2VDC 2300mAh Operating Time Up to 4 hours Operating Temperature 23ºF to 104ºF 5ºC to 45ºC Storage Temperature 4ºF to 158ºF 20ºC to 70ºC Humidity 5 to 95 non condensing Ruggedness Survives 1 m 3 ft drop to concrete on all sides Communication Interfaces USB 2 0 to download Datalogs and software updates Storage 400 MB internal for measurements Power up ti...

Страница 7: ...surements QAM B ITU J 83 B ref 593360 MPEG image Modulations 64QAM and 256QAM Power 45 110dBuV 25 120dBuV opt 593235 Pre BER y Post BER 1 0E 3 1 0E 8 MER Up to 38dB C N Up to 40dB Constellation Digital Measurements DVB S MPEG image Power 45 110dBuV 25 120dBuV opt 593235 CBER 9 9E 2 1 0E 6 VBER 1 0E 4 1 0E 8 MER Up to 20dB C N Up to 20dB Constellation Digital Measurements DVB S2 MPEG image Modulati...

Страница 8: ...d hold for approximately 3 seconds 2 Back button Return to the previous menuorcloseaparameterentrywindow 3 Home button Return to the main menu 4 Navigation buttons Used to scroll through options 5 OK Button To confirm selection 6 Setup button Parameter window for the current function 7 LED Powering Indicates if the equipment is powering an external load 8 LED Charging Battery LED flashes while the...

Страница 9: ... 3 hour charge will provide approximately a 75 charge The charge management system will detect various conditions preventing charging such as a battery that is over a safe temperature About battery Important If the meter detects a shortcircuit or over consumption and it is not connected to the power supply it automatically shuts down To turn it on again it is necessary that it is connected to tyeh...

Страница 10: ...om of the meter Carefully remove the connector from the power board and then remove the battery 3 sec OFF 3 sec OFF 3 sec OFF Place the new battery and then connect it to the power board Replace the back cover of the meter Make sure that the cable is not trapped between the two covers Replace the screws of the back cover 3 sec OFF 3 sec OFF 3 sec OFF ...

Страница 11: ... level range will be activated automatically in your H30FLEX whenever you re gister it within 30 days after you turn it on for the first time Product operation 1 Channel Info Analog and digital channels are very different in terms of signal content and power distribution and thus require the advanced SLM techniques provided in the Televes H30FLEX In analog mode video and audio levels V A and Carri...

Страница 12: ...and will set the slot with the meter parameters frequency band powering and DiSEqC In addition a SCR icon will be shown in the bar at the top SCR3 to indicate thar the slot is enabled While the slot is enabled all the setting changes of the meter will be applied to the currently slot SCR3 Tuning Channel Frequency A D Auto Analog Digital Save datalog Saves the current scan measurements You can see ...

Страница 13: ...portional to signal level in the spectrum trace relativo to reference level It is recommended to set the reference level manually as well as to select the span to include a frequency range wide enough The audible signal becomes continuous when the signal leves is close to the reference level Then it is necessary to increase the reference level to get a more accurate adjustment This is a useful fea...

Страница 14: ... of the meter will be applied to the currently slot SCR3 Volume 4 System Scan This function scans the selected channel plan and detects every existing analog and digital channel in real time to determine the overall frequency response of the system The scan measurement leverages the location based thresholds to clearly show whether or not signal levels comply with the cable system s specifications...

Страница 15: ...og Saves the current scan measurements You can see the datalogs using the remote control application 5 Satellite Test This function checks that the input signal corresponds to the selected satellite and at the same time checks the proper reception of the selected transponders from 1 to 4 transponders To do that the meter performs all the measurements on those transponders First of all the user mus...

Страница 16: ...A bar graph is displayed with the height representing the power for digital channels and the level of the video carrier for the analog channels The measurements made for analog channels are video carrier level and V A For digital channels the measurements are power and C N The analog channels will have an extra smaller white bar indicating the level of the audio carrier 6 1 Main window Below is a ...

Страница 17: ...ing and DiSEqC In addition a SCR icon will be shown in the bar at the top SCR3 to indicate thar the slot is enabled While the slot is enabled all the setting changes of the meter will be applied to the currently slot SCR3 Zoom OFF 1st 2nd 3rd 4th Select a quadrant of the constellation to be represented for more detailed view Select Zoom OFF for the full constellation Tuning Channel Frequency Save ...

Страница 18: ...igitize the analog input signals It is specifically aimed for installation and maintenance of analog video surveillance systems The supported interface is composite RCA S VHS The input video formats that can be displayed are the following NTSC 720x480 30fps PAL 720x576 25fps To run the feature you just have to connect the input signal to the adaptor provided with the H30FLEX making sure that the a...

Страница 19: ...d changes automatically the audio carrier to a value according to the selected standard Audio Carrier 4 5 MHz 5 5 MHz 6 0 MHz 6 5 MHz Volume Time and Date Set current time hour and minutes and date day of the month month and year Energy Auto suspension Auto shutdown USBStorage onlyoldhwversion Connect your H30FLEX to your computer using the USB connector and turn USB Storage ON so you can use your...

Страница 20: ...e the first thing that you must do is to install the driver Once you have installed the corresponding driver open a web browser in your computer Chrome recommended Type http h30 flex in the address bar of your web browser and press Enter Then you can see the home window of the H30FLEX web application 2 If your H30FLEX is a new hardware version one connect your H30Evolution to the network using the...

Страница 21: ...e selected Datalogs Change calendar list display mode Datalogs list Visualize measurements ClickingonathecorrespondingbuttonofaDatalog of the list the measurements of that Datalog will be displayed 2 Plans In this window you can see all the channel plans of your H30FLEX They are grouped in three categories Terrestrial Satellite and Customer The Terrestrial and Satellite channel plan are the standa...

Страница 22: ...an dard channel plans corresponding to other geo graphic areas this is specially helpful for those pla ces located near the frontier between two areas To do that click on the Channel plan repository button Click on the geographical region you work in Once you have selected the channel plans click this button to upload them to the meter Unfold to see the list with the channel plans corresponding to...

Страница 23: ...e channel plans added from the repository will be uploades to your H30FLEX but none of the channel plans in your meter will be removed 3 SCR In this window you can setup the multiswitches The H30FLEX includes a list of multiswitches by default but you can add more or edit any of the existing ones 4 Quality Profiles Using the web application you can add new quality profiles The H30Evolution has two...

Страница 24: ...application ex plained in the paragraph 4 Update of the section Web Application But if your H30FLEX has an old hardware version there is another way to update it The second one isusing the USB Storage feature of the Setup Menu see section 9 Setup of the point Product Operation To update the firmware using this procedure fol low the next indications 1 The first thing that you must do is download th...

Страница 25: ...hort circuit at the RF input It is recommended to check the installation to find out why the short circuit is produced DC OUTPUT LIMIT EXCEED Switch DC OUTPUT off This message appears when the meter detects an excessive consumption from the device that is being powered It is recommended to turn off the powering feature of the H30FLEX DC AT RF INPUT Check installation This message appears when the ...

Страница 26: ...nit needs to be returned Televes will arrange for free shipping The unit will need to be appropriately packed for shipping In compliance with IATA Regulations when using our shipping service follow these instructions Label the package The equipment should fit as snugly as possible in the box It is recommended to use the original packing materials Attach the precaution label to the package DO NOT L...

Страница 27: ... CONFORMITY DECLARAÇÃO DE CONFORMIDADE DECLARATION DE CONFORMITE DICHIARAZIONE DI CONFORMITÀ DEKLARACJA ZGODNOŚCI KONFORMITÄTSERKLÄRUNG ΠΙΣΤΟΠΟΙΗΤΙΚΟ ΣΥΜΜΟΡΦΩΣΗΣ FÖRSÄKRAN OM ÖVERENSSTÄMMELSE ДЕКЛАРАЦИЯ СООТВЕТСТВИЯ نايب ةقباطملا www doc televes com ...

Страница 28: ......

Страница 29: ...593301_593302_593303_593304_593360_593361_1 00_005_EN ...

Отзывы: