APPENDIX B - S Register Summary
Register
Function
Range
Units
Default
S0
Rings to Auto-Answer
0-1
rings
1
S2
Escape Character
0-255
ASCII
43<+>
S3
Carriage Return Character
0-127
ASCII
13<CR>
S4
Line Feed Character
0-127
ASCII
10<LF>
S5
Backspace Character
0-127
ASCII
8<BS>
S7
Wait Time for Carrier
0-255
second
60
S10
Carrier Loss Disconnect Time
0-255
second
50
S12
Escape Prompt Delay
0-255
0.02sec
50
S14
Command Status Bitmap (read only)
S21
Equipment Status Bitmap (read only)
S22
Equipment Status Bitmap (read only)
S23
Equipment Status Bitmap (read only)
S50
Data forwarding idle time-out
0-255
0.1sec
2
S51
Primary Data forwarding character
0-255
ASCII
13<CR>
S52
Secondary Data forwarding character
0-255
ASCII
26<ctl-Z>
S53
Remote Party Address
Char.String
0303030
S60
Idle Mode
0-1
0
S61
Idle Guard Time
1-5
0.1sec
5
S62
PLC Break Control Signal Length
0-255
10msec
30
S63
Enable the detection function or Listening
time
0-10
0.01sec
3
S-REGISTER DEFINITIONS :
The behaviors of WINC 900A can be adjusted via the AT commands and the content of register
to meet application’s requirement.
S0 Rings to Auto-Answer
Whether this unit will be able to answer the request for connection from the
remote caller automatically or manually is decided by the content of the
register 0.
S2 Escape Character
The value in register 2 maps to an ASCII code, a designated Escape
Character on the keyboard, which allows user to switch the operation mode
of the communication software back to command mode from connection
mode by holding the “Shift” key and press this key three (3) times.
S3 Carriage Return Character
S4 Line Feed Character
S5 Backspace Character
S7 Wait Time for Carrier