Hardware 

The box contains: 

 

1 Qtanium 400 

 

4 mounting magnets 

 

Qtanium 400 Quick Install Card 

 

 

 

2.1 

Other Components Required 

You also need the following components before starting the installation: 

 

a power cable (see the following section for options) 

 

a cellular antenna  

 

a GPS antenna 

 

WIFI antenna (with WIFI option) 

 

 

 
You may also need any or all of the following components, depending on your installation: 

 

I/O cable(s) to connect digital or other types of auxiliary devices and sensors  

 

2.2 

Power Cable Options 

There are two choices of power cable: 

 

3 m (9.8 ft.) heavy duty 16-gauge wire, plastic armored sheath with choke 

 

6 m (19.6 ft.) heavy duty 16-gauge wire, plastic armored sheath with choke 

2.3 

I/O Cables for (Optional) Additional Connections  

There are three choices of ruggedized cable for optional additional connections: 

 

7-Way cable (SAP Code 10001345) for digital sensors or devices I/O 

 

18-Way cable (SAP Code 10001346) for auxiliary or serial devices I/O 

 

18-Way satellite modem cable (SAP 

Code 10001384) for

 connection to a Quake 

Satellite Modem and/or auxiliary or serial devices 

Note   If desired, you can mount the Qtanium 400 using high-powered magnets such as 
M5 or equivalent (not supplied). 

 

 
 

Note   The power cable and two antennas are the minimal requirement for tracking 
only. 

 

 
 

Содержание Qtanium 400

Страница 1: ...Qtanium 400 INSTALLATION MANUAL...

Страница 2: ...E POWER CABLE BUILT IN IPS UNIT 12 4 7 CONNECT THE EXTERNAL BATTERY BACKUP OR SOLAR PANEL OPTIONAL 13 4 8 CONNECT ANY OPTIONAL EQUIPMENT 14 4 8 1 Digital Inputs 14 4 8 2 Digital Outputs 16 4 8 3 Multi...

Страница 3: ...Qtanium 400 Installation Manual iii...

Страница 4: ...EXTENT PERMITTED BY LAW ALL REPRESENTATIONS AND WARRANTIES EXCEPT ANY WHICH MAY NOT LAWFULLY BE EXCLUDED ARE EXPRESSLY EXCLUDED INCLUDING WITHOUT PREJUDICE TO THE GENERALITY OF THE FOREGOING THE IMPLI...

Страница 5: ...tions 6 Digital I O and 2 Multi I O an internal battery that is charged from a permanent external power supply such as the asset s battery through the power cable When fully charged the internal batte...

Страница 6: ...choices of power cable 3 m 9 8 ft heavy duty 16 gauge wire plastic armored sheath with choke 6 m 19 6 ft heavy duty 16 gauge wire plastic armored sheath with choke 2 3 I O Cables for Optional Additio...

Страница 7: ...nium 400 has an IP 67 rating Teletrac Navman recommends that you mount it in a location that will provide maximum protection from dust water and vibration The Qtanium 400 is rated up to 70 C but Telet...

Страница 8: ...00 Installation Manual 8 due to the battery chemistry battery operation will be impaired at high temperatures in particular it will not charge when the temperature reaches or exceeds 45 C need to chec...

Страница 9: ...e To asset s battery negative before ground isolator switch black wire To asset s 12 24V uninterrupted supply red wire To asset s ignition run signal pink wire 6 Check that the power cable is long eno...

Страница 10: ...it is not a hazard to the users of the asset protected from heat sources and from chaffing on sharp edges connected to manufacturer s approved points and run along factory harnesses located where it...

Страница 11: ...e permanent power source This connection must be fused 3 Amp slow blow Assets with a positive side isolation disconnect switch Connect on the battery side hot side of the manual or electronic positive...

Страница 12: ...d apply adequate insulation to the wire 4 6 Connect the Power Cable Built in IPS Unit The new Qtanium has IPS built in and simplifies installations on assets that have a manual or electronic battery d...

Страница 13: ...holder Black Ground Battery Negative before ground isolator switch Brown Ground Asset chassis connection after ground isolator switch Orange External Backup Battery Optional If required connect an ext...

Страница 14: ...e based on I O from Digital Inputs This connectivity is provided through the 7 Way and 18 Way connectors on the front panel of the Qtanium 400 4 8 1 Digital Inputs The Digital Inputs must be connected...

Страница 15: ...Qtanium 400 Installation Manual 15...

Страница 16: ...ws STATE VOLTAGE High 0 5 V Low 0 2 V Disconnected 4 8 2 Digital Outputs The Digital Output s have an open collector transistor type arrangement and are controlled by the dispatcher through the Online...

Страница 17: ...Reference source not found Digital Outputs When configured for Digital Output Multi I O 1 and Multi I O 2 operate as for the DO 1 and DO 2 lines Analogue Inputs When configured for Analogue Input Mult...

Страница 18: ...also use some of the Multi I O and Digital Inputs for temperature event monitoring 4 8 6 Connect an 18 Way Cable Optional 1 To connect an 18 Way cable to the Qtanium 400 remove and retain the shippin...

Страница 19: ...Way satellite modem cable Satellite Modem for Qube 4 and Qtanium 400 Installation Manual 4 9 Power Up the Qtanium 400 When the installation is complete perform the following steps in the order listed...

Страница 20: ...ire see section 4 6 4 Start the engine and allow up to five minutes to initiate OnlineAVL2 DIRECTOR reporting 5 Check that OnlineAVL2 DIRECTOR shows an Ignition On event If not check the pink wire see...

Страница 21: ...nium 400 if necessary 2 Apply Tamper Evident Seal Liquid inspector s lacquer to all fuse holders the ground screw and all connectors and blanking covers on the Qtanium 400 as shown 3 Tidy all wires wi...

Страница 22: ...4 The Qtanium 400 may be outside an area with cellular data coverage Check cellular data coverage with the provider 5 The SIM card may need to be activated Call Teletrac Navman customer support to che...

Страница 23: ...he shipping plug from the 18 Way connector then re install the 18 Way cable if used or replace the blanking cover 8 Start the engine and wait 1 5 minutes for the Qtanium 400 to reboot Qtanium 400 with...

Страница 24: ...Qtanium 400 Installation Manual 24 6 Dimensions The mounting hole in each corner has a diameter of 5mm...

Страница 25: ...dBm HSPA data rates 5 76 Mbps upload 7 2 Mbps download HSPA Fallback EDGE GPRS GSM quad band COMPREHENSIVE I O Ignition Input 1 fixed bias Digital Inputs 4 programmable bias inputs Digital Outputs 2...

Страница 26: ...ectors 5 way power connector 5 pin 18 way serial 1 wire connector 18 pin 7 way I O connector 7 pin Serial Interface 2 2 wire RS 232 TX RX Ground 1 4 wire RS 232 TX RX RTS CTS Ground PHYSICAL Dimension...

Страница 27: ...wire cable Qtanium 7 way I O cable Dallas 1 wire temperature sensors Dallas 1 wire iButton Driver ID reader Navman MDT860 Magellan Navigation PND Device M Nav 760 800 Serial Dallas 1 wire expander Wi...