![Teletek electronics LED63VG Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/teletek-electronics/led63vg/led63vg_quick-start-manual_1082356011.webp)
Voice Guide Keypad - LED63VG User Manual
11
Stopping the Alarm
The alarm is stopped by entering
a personal code:
CODE
After a valid code has been en-
tered, the message
“System dis-
armed”
will be repeated twice.
NOTE:
In the events of AC loss and
low battery, the
“AC power is lost”
or
“Battery discharged”
messages
will sound correspondingly 3 times
every 5 seconds.
Ambush Code
Ambush code is a personal code
that disarms the system, but still
sends an alarm signal. Its purpose
to indicate that the user is forced
to disarm the system against his/
her will. The ambush code is cal-
culated from the personal code by
adding 1 to the last digit.
If the last number is 9, it is replaced
by 0 in the ambush code.
Example
:
Personal code: 4615 Ambush
code: 4616
Personal code: 4619 Ambush
code: 4610
After a code has been entered, the
“System disarmed”
message will be
repeated twice.
User Level Program-
ming
As a rule of thumb you can enter
user programming mode using the
following procedure:
Step 1:
Enter a valid user code
Step 2:
Press
PRG
once
Step 3:
Enter a parameter num-
ber (one digit - see address table)
Step 4:
Change parameter value
Step 5:
Press
ENT
to confirm
and
CLR
to reject changes.
A blinking
RDY1
LED indicates that
the system is in programming
mode.
Voice Guide Keypad - LED63VG User Manual
14
Event Description
Code
1
2
3
4
5
6
Zone/User
Alarm
activated
1
1 2 3 4 5
6
Zone number
Alarm
deactivated
2
1 2 3 4
5
6 Zone
number
Fire
alarm
activated
3
1 2 3 4
5 6
Zone number
Fire alarm deactivated
4
1 2 3
4
5 6 Zone
number
Panic alarm activated
5
1 2 3
4
5
6
Zone number
Panic alarm deactivated
6
1 2 3
4 5
6 Zone
number
Tamper alarm activated
7
1 2 3
4 5 6
Zone number
Tamper alarm deactivated
8
1 2
3
4 5 6 Zone
number
Medical alarm activated
9
1 2
3
4 5
6
Zone number
Medical alarm deactivated
10
1 2
3
4
5
6 Zone
number
Zone bypassed
11
1 2
3
4
5 6
Zone number
Zone de-bypassed
12
1 2
3 4
5 6 Zone
number
Fire zone bypassed
13
1 2
3 4
5
6
Zone number
Fire zone de-bypassed
14
1 2
3 4 5
6 Zone
number
Panic zone bypassed
15
1 2
3 4 5 6
Zone number
Panic zone de-bypassed
16
1
2
3 4 5 6 Zone
number
Tamper zone bypassed
17
1
2
3 4 5
6
Zone number
Tamper zone de-bypassed
18
1
2
3 4
5
6 Zone
number
Medical zone bypassed
19
1
2
3 4
5 6
Zone number
Medical zone de-bypassed
20
1
2
3
4
5 6 Zone
number
Disarming
21
1
2
3
4
5
6
User
Remote disarming
22
1
2
3
4 5
6 User
Disarming by switch
23
1
2
3
4 5 6
Zone number
Arming
24
1
2 3
4 5 6 User
Remote arming
25
1
2 3
4 5
6
User
Arming by switch
26
1
2 3
4
5
6 Zone number
Quick arming
27
1
2 3
4
5 6
None
Engineer menu entry
28
1
2 3 4
5 6 17
Engineer menu exit
29
1
2 3 4
5
6
17