Teletek electronics LED63VG Скачать руководство пользователя страница 11

Voice Guide Keypad - LED63VG User Manual

11

Stopping the Alarm

The alarm is stopped by entering

a personal code:

CODE

After a valid code has been en-

tered, the message 

“System dis-

armed”

 will be repeated twice.

NOTE: 

In the events of AC loss and

low battery, the 

“AC power is lost”

or 

“Battery discharged”

 messages

will sound correspondingly 3 times

every 5 seconds.

Ambush Code

Ambush code is a personal code

that disarms the system, but still

sends an alarm signal. Its purpose

to indicate that the user is forced

to disarm the system against his/

her will. The ambush code is cal-

culated from the  personal code by

adding 1 to the last digit.

If the last number is 9, it is replaced

by 0 in the ambush code.

Example

:

Personal code: 4615   Ambush

code: 4616

Personal code: 4619   Ambush

code: 4610

After a code has been entered, the

“System disarmed”

 message will be

repeated twice.

User Level Program-

ming

As a rule of thumb you can enter

user programming mode using the

following procedure:

Step 1:

 Enter a valid user code

Step 2:

 Press 

PRG

 once

Step 3:

 Enter a parameter num-

ber (one digit - see address table)

Step 4:

 Change parameter value

Step 5:

 Press 

ENT

 to confirm

and 

CLR

 to reject changes.

A blinking 

RDY1

 LED indicates that

the system is in programming

mode.

Voice  Guide  Keypad  -  LED63VG  User  Manual

              14

Event Description

 

Code

 

1

 

2

 

3

 

4

 

5

 

6

 

Zone/User 

 

Alarm 

activated 

1 2 3 4 5 

Zone number 

Alarm 

deactivated 

1 2 3 4 

6 Zone 

number 

Fire 

alarm 

activated 

1 2 3 4 

5  6 

Zone number 

Fire alarm deactivated 

1  2  3 

5 6 Zone 

number 

Panic alarm activated 

1  2  3 

Zone number 

Panic alarm deactivated 

1  2  3 

4  5 

6 Zone 

number 

Tamper alarm activated 

1  2  3 

4  5  6 

Zone number 

Tamper alarm deactivated  

1  2 

4 5 6 Zone 

number 

Medical alarm activated 

1  2 

4 5 

Zone number 

Medical alarm deactivated 

10 

1  2 

6 Zone 

number 

Zone bypassed 

11 

1  2 

5  6 

Zone number 

Zone de-bypassed 

12 

1  2 

3  4 

5 6 Zone 

number 

Fire zone bypassed 

13 

1  2 

3  4 

Zone number 

Fire zone de-bypassed 

14 

1  2 

3  4  5 

6 Zone 

number 

Panic zone bypassed 

15 

1  2 

3  4  5  6 

Zone number 

Panic zone de-bypassed 

16 

3 4 5 6 Zone 

number 

Tamper zone bypassed 

17 

3 4 5 

Zone number 

Tamper zone de-bypassed 

18 

3 4 

6 Zone 

number 

Medical zone bypassed 

19 

3 4 

5  6 

Zone number 

Medical zone de-bypassed  

20 

5 6 Zone 

number 

Disarming  

21 

User 

Remote disarming 

22 

4  5 

6 User 

Disarming by switch 

23 

4  5  6 

Zone number 

Arming  

24 

2  3 

4 5 6 User 

Remote arming 

25 

2  3 

4 5 

User 

Arming by switch 

26 

2  3 

6  Zone number  

Quick arming 

27 

2  3 

5  6 

None 

Engineer menu entry 

28 

2  3  4 

5 6 17 

Engineer menu exit 

29 

2  3  4 

17 

 

Содержание LED63VG

Страница 1: ...VOICE GUIDE KEYPAD LED63VG 18020502_A_en_LED63VG...

Страница 2: ...e manufacturer reserves the right to change the specifications of the equipment described in this manual without notice This document contains information proprietary to the manufacturer No part of th...

Страница 3: ...view 12 Events Memory Review 13 Chime Enable Disable 15 Manager Level Programming 16 Manager Code Change 16 Changing User Code Rights 17 Events Memory Review 19 Chime Enable Disable 19 Bypassing 20 Se...

Страница 4: ...rod uct to fail to perform as expected Warnings Before using the LED63VG Keypad please make sure that you have read and understood the following instructions Always make sure that the LED63VG Keypad i...

Страница 5: ...uency increases Technical problem two short beeps indicating a technical prob lem Chime short beeps with subse quently increasing frequency indi cating intrusion into a zone with an activated chime op...

Страница 6: ...personal code CODE MEM Press to for a previous event and for a following one Press the ENT key to see more information on a zone number or a user code Information on the events as well as the zone nu...

Страница 7: ...Alarm memory Activated zone detector Voice Guide Keypad LED63VG User Manual 18 Now the manager can switch over between code change mode and user permissions mode using the and keys Originally the sys...

Страница 8: ...stay arming key se quence ARM 1 The BPS LED lights up permanently on the display and the LEDs cor responding to the numbers of the zones which are not armed blink slowly 17 The new code has been acce...

Страница 9: ...k slowly Voice Guide Keypad LED63VG User Manual 16 Manager Level Pro gramming As a rule of thumb you can enter user programming mode using the following procedure Step 1 Enter valid user code Step 2 P...

Страница 10: ...has been en tered the message System dis armed will be repeated twice If no valid code has been entered during entry time the System is armed message will sound If an alarm has been triggered in the...

Страница 11: ...em is in programming mode Voice Guide Keypad LED63VG User Manual 14 Event Description Code 1 2 3 4 5 6 Zone User Alarm activated 1 1 2 3 4 5 6 Zone number Alarm deactivated 2 1 2 3 4 5 6 Zone number F...

Страница 12: ...Events Memory Review To review event memory the user is required to enter a valid personal code CODE MEM NOTE Certain users may not be allowed to review event memory Press to for a previous event and...

Отзывы: