CA824 Installation manual
25
Adjusting the DIO32 module
To adjust the DIO32 module use JP1, JP2 and JP3 jumper connectors:
- JP1:
Where the JP1 jumper connector has been placed, the board-located zoom repeats the PGM output
status – the PGM zoom emits a continuous sound signal if PGM output is active.
Where the JP1 jumper connector has been removed, the board-located zoom is switched off. This does
not interfere with PGM output performance.
- JP2:
Where the JP2 jumper connector has been placed, the LED indication outputs will visualize the system
zone status. Depending on the configuration adjustments with JP3 jumper connector, the status of 1 to
32 or 33 to 64 zones will be displayed.
Where the JP2 jumper connector has been removed, the LED indication outputs will visualize the sys-
tem area status as follows:
—> the left-hand side coupling light-emitting diodes (1 to 16):
constant light
– the area is in ALARM or MEMORY state
no light
– the area is in regular NORMAL state
—> the right-hand side coupling light-emitting diodes (17 to 32):
constant light
– the area is armed
no light
– the area is disarmed
- JP3:
Where the JP3 jumper connector has been placed, the LED indication outputs will visualize the status of
zones 33 to 64 zone. The JP2 jumper connecter has to be placed.
Where the JP3 jumper connector has been removed, LED indication outputs will visualize the 1 to 16
zone status. The JP2 jumper connector has to be placed.
Zone information data is as follows:
LED blinks
– the zone is in TAMPER or FIRE state
constant LED light
– the zone is in ALARM or MEMORY state. Where the zone is in neither of the
specified states, this indication means an open/closed zone
no LED light
– the zone is in normal state.
LED brightness can be regulated with the help of the LED LIGHT CONTROL potentiometer.
A normal open contact button can be connected to the TEST clamps. Regular check-ups of mnemo-
panel integrity can be performed.
Pressing and holding the TEST button until all LEDs light up permanently can initiate the mnemo-panel
integrity test. LED1 only will be displayed after the button is released (see Fig. 16). A single click will take
you over to the following LED – 2, 3, 4 … 32. The next TEST button click will resume mnemo-panel
operation mode.
!Mnemo-panel operation mode will automatically resume if the TEST button is not pressed within
30 seconds!
Technical specifications of DIO32 module
Inputs - none
Outputs - 1 potential, duplicated with relay; sound indication option together with output status indication
LED outputs - 32
Quad system bus for connecting to control panel - Bus Connection
Consumption - max 200 mA (LED’s connected)
Auxiliary devices power supply (+AUX and +PGM from control panel) - 13,8 V / 2 A
Working temperature - (0°C) to (+50°C)
DIO module dimensions - 125 x 85 mm
Support openings dimensions - 114 x 67 mm