CA824 Installation manual
11
Idle device inputs (INPx) can be connected to the detectors as per the selected connection scheme.
The possible options for connecting the detectors to the inputs are given in Fig. 3. Attention must be paid
to programming the type of input connection in the system. The status of the Wire EOL and Doubling
configurations is indicated for every connection option.
!The Wire EOL and DOUBLING parameters have to be configured for all system inputs!
The necessary balance resistors have been placed in the spare parts pack accompanying the module.
!The sensors with contacts that by-pass the 1 k
Ω
resistors form first zone in double zoning, and
the sensors with contacts that by-pass the 2 k
Ω
resistors form second zone!
Fig. 3 Connecting sensors to CA824 system
inputs
NC
NC
1K
2,2K
Zone input
GND
Without EOL
(Wire EOL=OFF, DOUBLING=ON)
Double style
NC
NC
TAMPER
TAMPER
1K
2,2K
GND
Zone input
Without EOL, Open line recognition TAMPER
(Wire EOL=OFF, DOUBLING=ON)
TAMPER
TAMPER
NC
NC
GND
Zone input
1K
2,2K
EOL
1 k
With EOL, Open line and Short on line
recognition (TAMPER)
(Wire EOL=ON, DOUBLING=ON)
Single style
TAMPER
NC
EOL
1K
1K
Zone input
GND
With EOL, Open line and Short on line
recognition (TAMPER)
(Wire EOL=ON, DOUBLING=OFF)
Without EOL
(Wire EOL=OFF, DOUBLING=OFF)
NO
Zone input
GND
Normally open
1K
NC
Zone input
GND
Normally closed
1K
Содержание CA824
Страница 32: ...18020325...