background image

Installation and Operation

Managing the Lightspeed Server

18

Lightspeed K80 Server Guide

Managing the Lightspeed Server

IPMIView management software provides remote network management of one or 
more Lightspeed Servers using IPMI messages over Ethernet LAN or a dedicated IPMI 
LAN. If your Lightspeed Ethernet connector is used to connect to storage, you can use 
the IPMI LAN connector to create an IPMI network among your Lightspeed Servers. 

You can download IPMIView from the OEM, Supermicro, at this location: 

ftp://ftp.supermicro.com/utility/IPMIView/

You’ll find the manual at this location: 

ftp://ftp.supermicro.com/utility/IPMIView/IPMIView20.pdf

Among the tasks you can perform using IPMIView are these (see the manual for details):

Discover Lightspeed Servers on the IPMI network (requires dedicated IPMI LAN)

View system event logs

Check current sensors and monitor history of fans, voltages, temperature, and 
power supplies

View firmware revision levels

Perform various kinds of shutdowns and resets

Blink the UID LED to locate a particular unit in the rack or server room

Set fan speed

Manage LAN configuration, SNMP configuration, and RS232 modem

Manage users, passwords, and privileges

Set up paging of users in the event of malfunctions

Establish Text Console Redirection or KVM Console Video Redirection for remote 
system control via text display or full graphic display

Access virtual media 

Set up server management groups

Update firmware

For detailed instructions about using any of these system management features, 
consult the IPMIView User’s Guide.

Содержание Vantage Lightspeed K80

Страница 1: ...Lightspeed K80 Server Guide Serial Lightspeed K80 Server Guide 74 0362 00 166702 July 2015 Lightspeed K80 Server Guide...

Страница 2: ...echnology licensed from Fraunhofer IIS and Thomson Multimedia Google VP6 and VP8 Copyright Google Inc 2014 All rights Reserved MainConcept MainConcept is a registered trademark of MainConcept LLC and...

Страница 3: ...THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL...

Страница 4: ...MAY BE OBTAINED FROM MPEG LA LLC SEE HTTP WWW MPEGLA COM MPEGLA AVC THIS PRODUCT IS LICENSED UNDER THE AVC PATENT PORTFOLIO LICENSE FOR THE PERSONAL USE OF A CONSUMER OR OTHER USES IN WHICH IT DOES NO...

Страница 5: ...te agreement between Telestream and You if any Telestream is under no obligation to maintain or support the Software and Telestream has no obligation to furnish you with any further assistance technic...

Страница 6: ...by you for the Product Damages TELESTREAM LLC SHALL NOT BE LIABLE TO YOU FOR ANY DAMAGES INCLUDING ANY LOST PROFITS LOST SAVINGS OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF YOUR USE O...

Страница 7: ...Number MNL 1625 available at www supermicro com support resources results cfm Click Manuals and then download the manual by locating the SS1028GR TRFT entry in the Product column and clicking Download...

Страница 8: ...erver 1028GR TRFT with custom removable front bezel Lightspeed Server Guide this document Two US power cords US shipments for auto ranging power supply OR Two US and two UK or EU power cords UK Intern...

Страница 9: ...PS with surge protection Fluctuations in commercial supply voltage can damage unprotected electronic equipment A high quality surge suppressor may be substituted if a UPS is not available but it may n...

Страница 10: ...unknown add in cards will void the product warranty Following is a current list of approved Lightspeed Server add in cards and their corresponding part numbers These are listed on the Lightspeed Serv...

Страница 11: ...interface buttons and LEDs The back plane has an optional Fibre channel card Front Bezel LED Indicators and Buttons The removable front bezel provides a system monitoring and control interface featur...

Страница 12: ...ld properly disconnect client programs and shut down the domain and OS before cycling power Rear Panel Ports and Connectors In addition to the ports and connectors specified in the SuperMicro Server U...

Страница 13: ...with and utilize its credentials This user account should have read write permissions as nec essary for Vantage to have access to all input monitor watch and output locations and devices see Before y...

Страница 14: ...Data Execution Prevention DEP for essential Windows programs and services only 4 Disable User Account Control UAC as follows In Start Control Panel User Accounts Change User Account Control Settings...

Страница 15: ...sts the Vantage domain database Restart the renamed server and add all Vantage services to the renamed domain Note To complete this procedure your Windows user must have permission to rename the compu...

Страница 16: ...name and password for an account that has permission to rename this computer in the Windows domain 12 Restart the server 13 Start the Vantage Management Console select the new domain to manage and lo...

Страница 17: ...ces on the Lightspeed Server to the new Array domain just like any Vantage Services running on any Windows Server In an Array environment Vantage automatically detects that the services running on a L...

Страница 18: ...m using IPMIView are these see the manual for details Discover Lightspeed Servers on the IPMI network requires dedicated IPMI LAN View system event logs Check current sensors and monitor history of fa...

Страница 19: ...ntage Information Assistance FAQs Forums Upgrades Website www telestream net telestream support vantage support htm Support Email support telestream net Telestream Website www telestream net Sales and...

Страница 20: ...ay damage the unit and may invalidate your warranty If your Lightspeed Server needs service of any kind regardless of whether you purchased the Lightspeed Server from Telestream or an authorized resel...

Отзывы: