RESET THE WEB SERVER PARAMETERS
Assume that you have programmed the PX24U/PX24M system by editing many
parameters including web server settings and saved these. For any reason, IP address,
Login ID, password and HTTP port number have been forgotten and it is not possible
to reconnect to the web server of your PX24U/PX24M system. And, you need to
reconnect to the system (or reset the web server settings) without loosing any other
parameters, which are previously set.
First step is to restart the PX24U/PX24M system with factory default settings (see the
next topic). When the system starts up, the factory default IP address of the system is
10.0.0.12 and the port address is 80. There is no login ID or password for web browser
connection.
Connect to the system with a web browser ( 10.0.0.12, port 80, no login ID and
password). Operate the
WsReset
command or item in Homepage.
IMPORTANT: NEVER OPERATE THE SAVE COMMAND AFTER WSRESET.
OTHERWISE, PRE-PROGRAMMED PARAMETERS ARE LOST. YOU MUST
REBOOT THE SYSTEM JUST AFTER CONFIRMING WSRESET.
Next step is to reboot (or power down and up) the system.
The system starts up with all the parameters, which are previously programmed, but:
•
without any Login ID (name)
•
without any password
•
and HTTP port as 80
REBOOTING THE SYSTEM, PROGRAMMED PARAMETERS, FACTORY
DEFAULTS
Memory Locations for Programmed Parameters:
The programmed parameters are stored in two locations in the PX24U/PX24M
system:
•
the nonvolatile storage memory,or
•
the volatile operational memory (RAM)
Any parameter, modification, except stated explicitly, is written to the volatile RAM
and activated immediately. Without saving parameters to nonvolatile memory,
resetting, restarting, rebooting the PX24U/PX24M system will result in non-
recoverable loss in modifications.
Once stored into the nonvolatile memory, the stored parameters are downloaded back
to the RAM during a normal restart or power-up (except factory restart procedures,
which download factory default values into the RAM).
Restarting the System with Factory Defaults:
The parameter (
Param
) button on the front panel of PX24U/PX24M is to restart the
system with factory default settings. To reset the parameters, the PX24U/PX24M
system is powered up with the parameter button pressed hold. Be aware that the
parameter button must be hold pressed until the status led, which is also on the
systems blinks.
When the
Status
led blinks, i.e., the PX24U/PX24M system starts up, the parameter
button is released. The factory default IP address of the system is 10.0.0.12 and the
port address is 80. There is no login name or password for web browser connection.