HouseControl E+ Installation Manual
Hide the excess of the cable. Connect the installation cable to the Door
connector as depicted in the separate wiring
diagram.
Drill a hole in the door frame for flush mounting. Push the switch in the hole
with your hands.
Note! Do not use hammer.
Alarm is not activated immediately when the door is opened. The user must have some time to cancel
the alarm from the security keypad when coming in (see User’s Manual).
Note: Install the switch on the opposite side of the hinges.
3.11 Moisture Sensor
Moisture sensors are available as accessories. Install the sensor under a bypass manifold or a
dishwasher. If there is a leakage in the water pipe, water will flow in the casing pipe and come out near
the bypass manifold and eventually end up in the floor drain. By placing the moisture sensor under the
bypass manifold you can detect leakages easily.
Tape the sensor to the floor.
Hide the excess of the cable. Connect the moisture sensor to the
Water connector as depicted in the
separate wiring diagram.
3.12 Motion Sensor
Motion sensor should be installed in the living area where it has the best coverage for sensing
movement.
Do not install motion sensor in entrance hall if security keypad is in the same space. The user must be
able to come in and switch monitoring off from the security keypad without activating the motion sensor.