background image

14 

 

HouseControl E+ Installation Manual 

The  operating  mode  does  not  change  immediately  if  you  use  security  keypad.  There  is  a  30  second 
delay when switching monitoring off and a 45 second delay when switching monitoring on. There are no 
delays if you use text messages 

ALARM ON

 and 

ALARM OFF 

except the time it takes the message to 

travel in the GSM network. 

When testing the system you can silence the siren by using a proximity key (the operating mode does 
not change if alarm is active). 

1.  Magnetic  door  switches.  Send 

ALARM  ON 

message  to  the  unit  and  trigger  an  alarm  by 

opening a door or a window with magnetic door switches. Wait until you receive an alarm text 
message. Send 

ALARM OFF

 to the unit to clear alarms. 

2.  Moisture  sensor.  Drop  some  water  on  the  sensor  so that  it  alarms. Wait  until  you  receive  an 

alarm message. Send 

ALARM OFF

 to the unit to clear alarms. 

3.  Motion  sensor.  Send 

ALARM  ON 

message  to  the  unit  and  go  inside  the  house  so  that  the 

motion sensor detects you. Wait until you receive an alarm message. Send 

ALARM OFF

 to the 

unit to clear alarms. 

4.  Smoke detector. Test the detector as instructed by the smoke detector manufacturer. The alarm 

must  be  at  least  10  seconds  long  for  HCE+  to  react  to  it.  Wait  until  you  receive  an  alarm 
message. Send 

ALARM OFF

 to the unit to clear alarms. Notice that both sirens, the siren in the 

smoke  detector  and  the  siren  connected  to  HCE+,  must  go  on  when  there  is  an  alarm. 
Exception: if interconnect feature is enabled in the smoke detectors, every smoke detector siren 
should alarm. 

5.  Carbon monoxide detector. Test the detector as instructed by the manufacturer. Wait until you 

receive an alarm message. Send 

ALARM OFF

 to the unit to clear alarms. 

6.  Enabling remote camera. Send 

CAMERA ON

 message to the unit, and then ask report from the 

unit with command 

?

. Check that the camera is enabled (CAMERA: ON) from the report. 

7.  Taking pictures with remote camera. You must tell HouseControl the multimedia settings (MMS) 

of the particular GSM subscription before it can send pictures. In addition, some operators may 
require an explicit activation of these settings. If this is the case, place the SIM card in an MMS 
capable  phone  and  consult  your  operator  for  further  instructions.  You  will  usually  find  the 
multimedia settings and activation instructions from telecommunications operators’ web pages. 

Command 

Explanation 

Example command 

MMSAPN 

Access point name 

MMSAPN xxx.xxx.xx 

MMSURL 

URL address 

MMSURL http://xxx.xx.xx 

MMSIP 

Gateway IP address 

MMSIP xx.xx.xx.xx 

MMSPORT 

Port number 

MMSPORT xxxx 

MMSUSERNAME 

User name 

MMSUSERNAME 

MMSPASSWORD 

Password 

MMSPASSWORD 

 

You can take a picture with command 

PICTURE

 (see User’s Manual) if the multimedia settings 

are ok. 

8.  Heater relay. Send 

HEATER ON

 and 

HEATER OFF

 messages to the unit and make sure the 

heater starts and stops. 

9.  Ext relay. Send 

EXT ON

 and 

EXT EI

 messages to the unit and make sure the controlled device 

works as expected. 

10.  Send 

ALARM ON

 and 

ALARM OFF

 commands to the unit and make sure that the status light 

on the security keypad displays the unit’s operating mode correctly. 

11.  Unplug the battery backup unit and wait until you receive an alarm message. It may take 15 to 

30 minutes for the alarm to activate. Plug the battery backup unit back in after you received the 
alarm message and wait until you receive Power OK message. 

Содержание HouseControl E+

Страница 1: ...ANUAL 1 0 HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY SECURITY KEYPAD WITH PROXIMITY TAGS PREVENTION OF WATER DAMAGES WIRELESS EXTENSIONS ...

Страница 2: ......

Страница 3: ...ector model Motion sensor model Magnetic door switches Remote camera Security keypad Siren Installed by We assure that the alarm system was installed in accordance with the manufacturer s instructions that the alarm system has been tested and it works as documented that the end user has received guidance as to how to use the alarm system Location and date Installed by Signature This form needs to ...

Страница 4: ......

Страница 5: ...MOTE CAMERA 6 3 6 INDOOR TEMPERATURE SENSOR 6 3 7 OUTDOOR TEMPERATURE SENSOR 6 3 8 WATER TEMPERATURE SENSOR 7 3 9 SIREN 7 3 10 MAGNETIC DOOR SWITCHES 7 3 11 MOISTURE SENSOR 8 3 12 MOTION SENSOR 8 3 13 SMOKE DETECTOR 9 3 14 SECURITY KEYPAD 10 3 15 HEATER RELAY 11 3 16 EXT RELAY 11 3 17 POWER SUPPLY AND BATTERY BACKUP UNIT 12 3 18 SIM CARD 12 3 19 WIRELESS EXTENSION 13 4 SETUP AND TESTING 13 4 1 TES...

Страница 6: ...munications operator for testing and using HouseControl You must disable the PIN code request from the SIM card before inserting the card in the central unit It is recommended that testing is conducted with the same SIM card that will remain in the central unit after the installation is complete If a camera is installed you should make sure that MMS messages messages that contain pictures can be s...

Страница 7: ...ctor HCE Wireless extension detectors and remote controls Magnetic door switch flush and surface mounting Temperature sensors Battery Moisture sensor Battery backup unit package Central unit package Check the package contents Central unit Magnetic door switch flush mounting 2 temperature sensors Siren Motion sensor Smoke detector Battery backup unit And Materials needed in installation Installatio...

Страница 8: ...ter Aircon relay see 3 3 2 Ext relay see 3 3 3 Camera and data connector 4 Inputs for temperature sensors siren magnetic door switches moisture sensor motion sensor smoke detector security keypad and 12V power supply see 3 3 5 Cable holder 6 SIM card slot 7 Power switch 8 Tamper switch 9 Manual heating switch red light is on when manual control is used 10 Door security on off switch 3 3 Connectors...

Страница 9: ...r switch or without the motion sensor being able to detect the trespasser You must have an access to the central unit if you intend to use door security at night The signal light on the security keypad tells the current operating mode is monitoring on or off Drill holes for the cables on the wall Leave at least 30 cm of surplus length to the cables to make installation easier Push surplus cable ba...

Страница 10: ...tom 3 6 Indoor Temperature Sensor Place the indoor temperature sensor in the living area in an unnoticeable place Run the cable behind a baseboard to the HCE Note Do not leave sensors uninstalled Shorten cables as needed and install temp1 and temp2 sensors inside HCE so that there will be no unnecessary temperature alarms Place the temperature sensor in the area where you want to measure temperatu...

Страница 11: ...ust not exceed 300mA 12VDC Fasten the siren with the screws included in the package Connect the siren to the Siren connector as depicted in the separate wiring diagram Notice polarity black and red wires 3 10 Magnetic Door Switches Connect magnetic door switches in series as shown in the separate wiring diagram Install them in doors and windows that are most usually left open by accident This prev...

Страница 12: ...ll the sensor under a bypass manifold or a dishwasher If there is a leakage in the water pipe water will flow in the casing pipe and come out near the bypass manifold and eventually end up in the floor drain By placing the moisture sensor under the bypass manifold you can detect leakages easily Tape the sensor to the floor Hide the excess of the cable Connect the moisture sensor to the Water conne...

Страница 13: ...r ceiling Hide the surplus of the cable Connect the motion sensor to the IR connector as depicted in the separate wiring diagram 3 13 Smoke Detector The smoke detector should be attached to the ceiling Do not place the detector in a corner or cranny because then it will not detect smoke so easily Note You can connect up to 8 smoke detectors in the fire connector in HCE Open the cover cerefully by ...

Страница 14: ...ode alarm on off Installer s key cannot be used for this purpose Operating mode can also be changed by using a secret code The codes are attached to the installer s key To program security keypad for example if you want to change individual codes you need installer s key and installer s code 1234 Do not change the installer code because if installer s proximity key is lost you cannot program the s...

Страница 15: ... house You can control an individual heater or an entire heating system with HCE Connect the heater to the central unit HEATER relay Note You cannot control heating from your mobile phone if manual control is turned on Important Make sure that max load 230VAC 10A is not exceeded under any circumstances Important When relay is used to steer inductive load for example another contactor connect RC fi...

Страница 16: ...e battery 3 Attach the battery to the casing with two sided tape 4 Connect the mains cable Make sure the HCE works even if you detach the mains cable from the wall outlet This proves that the battery has been connected properly and the 4A fuse is ok 3 18 SIM Card First disable the PIN code request from the SIM card Make sure the power is switched off from the HCE power switch is OFF see picture be...

Страница 17: ...M card in the central unit Switch power ON and leave the cover open Wait 30 seconds for the HCE to start up The unit s status light starts blinking as it goes into programming mode If the light does not blink make sure the PIN code request is disabled from the SIM card the GSM connection has been opened by your operator the GSM signal strength is sufficient in the area and that the SIM card was pl...

Страница 18: ... the detector as instructed by the manufacturer Wait until you receive an alarm message Send ALARM OFF to the unit to clear alarms 6 Enabling remote camera Send CAMERA ON message to the unit and then ask report from the unit with command Check that the camera is enabled CAMERA ON from the report 7 Taking pictures with remote camera You must tell HouseControl the multimedia settings MMS of the part...

Страница 19: ..._______________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ ____________...

Страница 20: ..._______________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ __________________________________________________________________________________________ ____...

Страница 21: ...SETUP AND TESTING 17 ...

Страница 22: ...18 HouseControl E Installation Manual Isoharjantie 6 Tel 358 20 728 8740 71800 Siilinjärvi Fax 358 17 462 1212 FINLAND info telemic fi http www telemic net ...

Отзывы: