Eye
III+
VXB
I
nstallation Guide
Page 28
Installation of
Eye
III
+
VXB
for Remote Monitoring
2.
Press
[Enter]
button to pop up the main menu, and enter the sub-menu
[TRANSMIITER
SETUP] -> [NETWORK SETUP]
.
3.
Select
[PROXY SERVER]
item and then press enter to edit the proxy sever IP address.
4.
You need to set edit each items of the
[PROXY SERVER SETUP]
menu. Select
[ENABLE]
item and user left/right arrow button to toggle select
[YES]
, enter the IP
address (eg. 192.168.0.2 as in the connection topology), and set the port number (default
value is 19001).
5.
Setup
sure
LINK
address and related settings as previous discussed.
6.
Reset
Eye
III+
VXB
so that all settings will take effect.
PC software installation procedures:
1.
On PC side, you need to install the Broadband dialer software and
Eye
proxy server
software.
2.
For Broadband dialer, consult your Broadband dialer software installation manual.
3.
Install
Eye
proxy server software, which is bundled with
Eye
III+
WRS3-AD
software.
4.
Start
Eye
proxy server, the following screen will pop up. Enter the transmitter IP (eg.
192.168.0.3) and port number (eg. 1024). The external port is the port number of the
dynamic real IP, which is used for other PCs on the Internet to access the transmitter.
[ NETWORK SETUP ]
TRANSMITTER IP
. . .
SURELINK
. . .
PROXY SERVER
. . .
GATEWAY IP 192.168.0.1
BUILT-IN WEB SERVER ENABLED
BACK
[ PROXY SERVER SETUP ]
ENABLE
NO
IP
0.0.0.0
PORT 0
BACK