E1. Connecting for telemetry control
Connect the RS485+/RS485- terminal of
Tele
Eye
Dialup CCTV
to the
RS485+/RS485- terminal of the speed dome respectively. Category 5 STP or UTP cable
is one of the choices for the RS485 cables.
E2. Connecting for alarm sensor input
Tele
Eye
Dialup CCTV
supports 4 alarms, or 3 alarms with 1 arm/disarm input. You
can directly connect the alarm sensors to the alarm port as illustrated in the following
diagram.
E3. Connecting for switch control
The switch output of
Tele
Eye
Dialup CCTV
can be used to control on/off of some
electrical device. However, the maximum rating for the switch output is 24VAC, 1A only.
If you want to use the switch to control device with large ratings, you can use the cascade
configuration. An example configuration is shown below.
Tele
Eye
Dialup
CCTV
Alarm port
Alarm 1
Alarm 2
Alarm 3
Alarm 4
Common
Sensor 1
Sensor 2
Sensor 3
Sensor 4
485-
Tele
Eye
Dialup CCTV
RS485 port
485 +
24Vac
220Vac
24Vac Relay
Fluorescent Lamp