background image

 

 

                                                                                                                                                                                                                      3 

II. Notice: 
 
Signal  Communications  Limited  reserves  the  right  to  make  improvements  to  the  product 
described in this manual at any time and without prior notice. 
 
This manual is copyrighted. All rights are reserved. This manual may not be copied, reproduced 
or translated in whole or part without prior consent from Signal Communications Limited. 
 
Tele  Eye  is  a  trademark  of  Signal  Communications  Limited  and  is  registered  in  China,  Hong 
Kong, US and other countries. 
 
TeleEye's products are sold under the brand name of CAMERIO in Australia, Japan, Korea, New 
Zealand, Taiwan and Argentina. 
 
CAMERIO is a trademark of Signal Communications Limited and is registered in Australia, Japan, 
Korea, New Zealand, Taiwan and Argentina.   
 
All other trademarks are the property of their respective owners 
Copyright  (c)  2007  Signal  Communications  Limited  (A  Member  of  TeleEye  Group).  All  rights 
reserved. 
 
Version 1.1 
 
Limits of Liability and Disclaimer of Warranty 
Signal  Communications  Limited  has  taken  care  in  preparation  of  this  manual,  but  makes  no 
expressed or implied warranty of any kind and assumes no responsibility for errors or omissions. 
 
No liability is assumed for incidental or consequential damages in connection with or arising out 
of the use of the information or accessories contained herein. 
 
Features and specifications are subject to change without prior notice. 

 

 

 

 

 

 

 

 

 

 

 

Содержание DM587

Страница 1: ...User Manual TeleEye DM587 DM589 High Speed Dome Before attempting to install or operate on this produce Please read this manual carefully and keep it for future use...

Страница 2: ...11 Chapter Three Fast Operation Guide of Dome Device I Wiring 12 II Setting protocol and baud rate 12 III Setting dome device address 13 IV Install camera 13 V Connect the power of dome device 13 VI C...

Страница 3: ...the view angle can be 90 or 92 degree 5 Pan manual operation speed can be 0 1 to 280 degree per second 6 Tilt manual operation speed can be 0 1 to 120 degree per second 7 128 pershot positions A fixed...

Страница 4: ...tina CAMERIO is a trademark of Signal Communications Limited and is registered in Australia Japan Korea New Zealand Taiwan and Argentina All other trademarks are the property of their respective owner...

Страница 5: ...f and other protecting measures should be carried out 6 Please avoid exposing the Dome video camera to rain or the humidity etc Please do not use the product in humid place If the video camera is inst...

Страница 6: ...w holes Fig III 1 Fig III 2 Step one Aim the open end of shield dome at the lens of camera Aim the 4 holes on the shield to the 4 M3 screw holes on the dome device as indicated in figure III 2 Step tw...

Страница 7: ...to wear cotton gloves when operate 2 As shown in the figure below first take the flexible flat cable through connector above the base plate and buckle it on the connector Then buckle the cable on the...

Страница 8: ...7 V Install Bend Tube Style Bracket Fig V 1 Connecting the dome to the wall mount with the bracket Fig V 2 Wall mount bracket installation...

Страница 9: ...is power on 2 Multi dome device connection When connecting many dome devices together the user can embed multi device system with auxiliaries such as arrester device video matrix DVR and alarm box fo...

Страница 10: ...On Off status Protocol type 1st digit 2nd digit 3rd digit 4th digit 5th digit 6th digit PELCO D ON ON OFF OFF PELCO P OFF OFF ON OFF TeleEye DM2 ON ON ON OFF Dome device controller Image displayer Pow...

Страница 11: ...OFF OFF 4800 OFF ON 9600 ON OFF 19200 ON ON This figure shows protocol of PELCO D Baud rate of 2400 Setting address for dome device this figure shows the address of dome device No 1 On Off switch Sett...

Страница 12: ...11...

Страница 13: ...Protocol PELCO D Baud rate 2400 bps Please refer to detailed parameter in next chapter This dip switch located on PCB in the dome device Protocol setting Baud rate setting Image displayer Cables RS 48...

Страница 14: ...of protocol of dome device is auto detection the protocol of keyboard controller can be set arbitrarily But its baud rate should be set identical with that of the dome device VII Start testing When a...

Страница 15: ...hot setup options 1 Numder 1 Preshot number selection Press OPEN or Joy stick left or right to enter The default number after entering is 001 hundred bit ten bit single bit Joy stick left or right to...

Страница 16: ...OSE When Done _ _ _ _ _ _ _ _ 0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z _ IRIS CLOSE When Done IRIS CLOSE When Done IRIS CLOSE When Done Press OPEN or joystick left or ri...

Страница 17: ...or right to enter 1 Default Function P V T Select default function Preshot Tour PTZ Press OPEN or Joy stick left or right to enter 2 Number 1 Function number selection Press OPEN or Joy stick left or...

Страница 18: ...tore default setting Press OPEN or Joy stick left or right to enter 3 Color system PAL NTSC PAL NTSC switch Joy stick left or right to select 4 Scan Camera Reset Null Restart dome camera Press OPEN or...

Страница 19: ...Change Name Loc Change display location of name Press OPEN or Joystick left or right to enter 3 Name Display ON OFF Name display On Off Joystick left or right to select IRIS CLOSE to Exit 4 Mask Sett...

Страница 20: ...enter 3 Program a Tour Enter PTZ tour programming Press OPEN or Joy stick left or right to enter 4 Run a Tour Run Pan Tilt Zoom tour pattern Press OPEN or Joy stick left or right to enter 5 Delete a...

Страница 21: ...16 IRIS CLOSE When Done Joystick arbitrarily to move the cursor and stop the cursor at place of programming Press OPEN to enter the selection Press OPEN continuously to select P Preshot T self study...

Страница 22: ...rms Press OPEN or Joystick left or right to enter This function is not available at the moment Name Num E N 1 _ _ _ 2 _ _ _ 3 _ _ _ 4 _ _ _ IRIS CLOSE to Exit P V T 1 128 0 0 1 2 3 4 5 6 7 8 9 IRIS CL...

Страница 23: ...and focus 3 Input the preset number 4 Press ENTER 5 Repeat step 2 to step 4 if you want to set more preset point 6 Press set key to exit Call Preset N PRESET 1 Input the preset number 2 Press ENTER Se...

Страница 24: ...is slow If S is within 81 160 the scan rate is medium If S is within 161 250 the scan rate is high Focus Control Generally the camera will automatically adjust the focus to get clearer image based on...

Страница 25: ...nic signal noise or the camera is directed to the monitor screen Grounding the dome device or shut off the surrounding big electronic devices electric HF signal generating equipment or rotate the came...

Страница 26: ...transmission Add driver Improper contact of control cable Check the circuit slip ring is demage Replace slip ring 10 Insensitive control of dome device RS 485 protective discharge arresters broken Ch...