TDMC+ Teledyne Dual Mode Charger  
 

 

Questions?   Write to: 

[email protected]

  

Page 12/15 

 

Or call: 1 (800) 456 0070 / 1 (909) 793 3131. 

 

 

 

 

Example 2: The Teledyne 7638-44 battery is a 24V, 44 Ah battery, 2A charge: 

 

The battery capacity is 44Ah, round to 45. 

 

Divide 45/2 = 22.5 

 

22.5 is not evenly divisible by 5, round 22.5 down to 20. 

 

On the table, select the same row as in (1), select the next column to the right, observe 
the answer 20 is to the right of 45. 

 

Go! Button: 

User initiated

 charge cycle 

 

After confirming charger configuration, press the button in Screen Section F to start the 
charge cycle. 

Details of the Two Stage Charge Mode 

1.

 

Stage 1: Constant Current 

 Bulk Charge 

With the battery in a discharged state, charging 
initiates in constant current mode.  Current is 
maintained at user specified current as the battery 
voltage increases.  The charger automatically 
progresses to Stage 2 based upon the battery 
voltage.  This stage is allowed a maximum of 6 hours. 

2.

 

Stage 2: Constant Voltage 

 Absorption 

When the battery voltage has reached the 16 or 32V 
set-point, charging continues in constant voltage 
mode for the selected duration.  Voltage is 
maintained as the charging current decreases. 

3.

 

Charge Complete 

 The charge cycle is complete  

 

 

 

 

 

 

Two Stage Charge Algorithm 

Содержание TDMC+

Страница 1: ...rights reserved TDMC Teledyne Dual Mode 12 and 24 VDC Lead Acid Battery Charger Redlands CA 92374 1 800 456 0070 1 909 793 3131 support teledynebattery com Product Name TDMC Part Number TDMC 01 Docume...

Страница 2: ...e 3 Product Description 4 Precautions and Warnings 5 Batteries 5 Location 5 Grounding and AC Power Cord 5 DC Output Connection 6 Charger 6 Personal Precautions 6 Charger Operation 7 Organization of th...

Страница 3: ...oltage mode User selects charger voltage for 12V or 24V operation as appropriate for the battery to be charged by pressing the button in Screen Section A Caution If a 12V battery is charged with a 24V...

Страница 4: ...Teledyne Battery Products TDMC is a battery charger for 12V and 24V lead acid batteries It offers two microprocessor controlled precision charging method a three stage charging method for normally dis...

Страница 5: ...smooth even uncluttered surface Allow adequate airflow around the unit during charging to prevent overheating Maintain minimum 3 7cm distance to wall Do not use the charger on a soft carpeted upholste...

Страница 6: ...C connection Make sure that the cable s terminals are free of any corrosion Charger Never operate a charger that has been damaged in any way including impact shock or excessive exposure to moisture pl...

Страница 7: ...g cable to the Positive terminal on the battery Connect the Negative Black charging cable to the Negative terminal on the battery Reversing these connections results in the charger displaying a Revers...

Страница 8: ...lete in the allotted time See charging Method details for allotted times Note in most Error conditions Selection Items A B C and D will vanish and the charger will not allow further operation until po...

Страница 9: ...ging Charger is idle Red Stopped on Error Red Green Charging Green Charge Complete Connection Red Battery is reverse polarity Red Green Battery not detected Green Battery is connected correctly Charge...

Страница 10: ...For Normally Discharged Lead Acid Battery Charge Method select End at 5A in Screen Section E With this selection the charger will follow the three stage charge mode recommended for use with all normal...

Страница 11: ...dition The Deeply Discharged or Sulphated Lead Acid Battery Charge Method ending condition is based on time The time should be based upon the battery capacity in amp hours and the desired charging cur...

Страница 12: ...the button in Screen Section F to start the charge cycle Details of the Two Stage Charge Mode 1 Stage 1 Constant Current Bulk Charge With the battery in a discharged state charging initiates in consta...

Страница 13: ...of Stage 1 2 10 80 hours selectable Max Absorption Voltage 15 0V 100mV 30 0V 100mV Unit Specifications Electrical Input Voltage 85 VAC 270 VAC 50 60 Hz Max Power 250 Watts Configuration Line neutral c...

Страница 14: ...ular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correc...

Страница 15: ...battery 5 Verify DMM matches voltage on screen 5V 6 Press Pause 7 Verify DMM matches voltage on screen 2V 8 Set DMM to current mode connect DMM in series with battery 10A mode 9 Resume charge press Go...

Отзывы: