37
64171LMP
Revision 3
PS200-LMP
PORTABLE GAS MONITOR
Natural Gas Measurements
The monitor is used to accurately measure natural gas. The accuracy is ±3% of reading when the
natural gas composition is as follows:
Methane (CH
4
):
≥ 90%
Ethane (C
2
H
6
):
≤ 5%
Propane (C
3
H
8
):
≤ 1.4%
Butane (C
4
H
10
):
≤ 0.5%
Inert
gas
(e.g.
Nitrogen (N
2
)):
≤ 3%