HDO4000 High Definition Oscilloscope
Edge trigger with holdoff by events.
Holdoff Settings
To access the Trigger Holdoff dialog, choose
Triggers > Trigger Setup
from the menu bar or press the
Front Panel Trigger Setup button, then touch the
Holdoff tab
.
Holdoff by
- type of holdoff to use with trigger: None, Time (clock), or Event.
Time
- if using Holdoff by Time, the time in S to wait before triggering.
Events
- if using Holdoff by Events, the number of events to count before triggering.
Starts Holdoff Counter On
- whether to count holdoff time/events from Acquisition Start or Last Trigger
Time before triggering again.