Teledyne Frontline Sodera Скачать руководство пользователя страница 10

Frontline Technical Support: Phone +1-434-984-4500 or email [email protected]

6. Click the

Analyzing

button, or click the

Stop Analyze

button

to stop analyzing. .

7. To clear captured data, click the

Clear

icon .

l

If you select

Clear

after stopping analysis, a dialog appears asking whether you want to save the data.

o

You can click

Save File

and enter a file name when prompted .

o

If you choose

Do Not Save

, all data will be cleared.

o

If you choose

Cancel,

the dialog closes with no changes.

l

If you select the

Clear

icon while a capture is occurring:

o

The capture stops.

o

A dialog appears asking if you want to save the capture

o

You can select

Yes

and save the capture or select

No

and close the dialog. In either case, the existing capture file

is cleared and a new capture file is started.

o

If you choose

Cancel

, the dialog closes with no changes.

12. Sodera Technical Specifications/Service Information

l

Dimensions: 159 mm wide X 57 mm tall” X 165 mm deep” (6.3” X 2.3 " 6.5" X mm)

l

Weight: 1.0 kg (2.2 lb)

l

Humidity: Operating: 0% - 90% (0 °C – 35 °C)

l

Temperature: -10 °C to +40 °C (14 °F to +104 °F)

l

Power Input: 12 VDC (tip positive)

l

Max Power: 25 W

l

Battery: NB2037FQ31

Caution:

There is a risk of explosion if the battery is replaced by an incorrect type. Dispose of old

batteries according to your local regulations.

Service Notes

The Sodera hardware does not contain any user serviceable items. Any repairs and maintenance must be performed by a service
technician that has been trained and approved by Frontline.

Before any service is performed on Sodera, all power sources must be removed. This includes removing the battery and disconnecting
any power sources from the 12 VDC input power connector on Sodera. Typical power sources include external AC/DC power supplies
or auxiliary power sources from a vehicle.

Internal Fuse Information

l

Manufacturer: Littlefuse

l

Type: OmniBlok

l

Current rating: 5A

l

Speed rating: Very Fast Acting

l

Voltage rating: 125V ac/dc

This quick start guide provides sufficient information to begin the data capture. Detailed hardware and software information is

contained in the ComProbe Sodera User Manual. The manual is available on FTE.com.

© 2016 Teledyne LeCroy, Inc.

The Bluetooth SIG owns the

Bluetooth

word mark and logos, and use of such marks is under license.

Содержание Frontline Sodera

Страница 1: ... l Free Hard Disk Space 20 GB Install Software l From Download Download the latest ComProbe installer from FTE com Once downloaded double click the installer and follow the directions http www fte com sodera soft 1 Front Panel Controls Frontline Sodera front panel is shown below The panel provides controls to power up and shut down the Frontline Sodera hardware and it provides indicators to show t...

Страница 2: ...ery present Green Constant Battery present and is at normal operating voltage Slow Flash Battery charging Amber Fast Flash Battery fault Host Interface None Off No host interface is connected Green Constant Host interface is connected Amber Constant Internal error Capture None Off Unit is not actively capturing data Green Constant Unit is capturing data Red Constant Unit has engaged RF overload pr...

Страница 3: ...ync IN OUT Used for synchronizing multiple capture devices Sodera can act as a clock source master device providing the clock to synchronize timestamping with connected target slave devices When operating as a master device the OUT RJ 45 connector provides the synchronizing clock The synchronizing clock can be attached to a slave Frontline Sodera or a Frontline 802 11 for example When operating as...

Страница 4: ...by providing the clock to the slave device receiving the clock The devices are connected in a daisy chain configuration The Sodera unit must be the master device Refer to the following tables to 2 Rear Panel Connectors on the previous page and to the 802 11 rear panel image below Sodera 802 11 Sodera 802 11 PROBESYNC OUT PROBESYNC IN OUT IN Master Slave X X Table 3 Sodera Synced to 802 11 Using a ...

Страница 5: ...the battery To start Sodera depress the Power button on the front panel for at least 1 2 second and then release This action will provide a clean start for Sodera hardware The battery charge state indicator LEDs will repeatedly flash in sequence while the unit powers up The front panel Power indicator LED will be green Should the front panel Power indicator begin blinking red the Sodera hardware i...

Страница 6: ...not required to specify the addresses of the devices to be captured or their roles master or slave during the connection lifetime Prior to capturing data the user does not need to enter any information PIN OOB long term key link key used to encrypt or decrypt data Sodera provides live simultaneous capture of all 79 Classic Bluetooth channels and 40 Bluetooth low energy channels storing data for bo...

Страница 7: ... automatically applied to the devices under test Prior to protocol analysis the user can enter any unknown keys Sodera will identify the specific key necessary for data decryption for example Link Key Passkey PIN Temporary Key Decryption keys are entered into the Sodera Security Pane Sodera Security Pane The user can configure the datasource from the Options menu The default settings are sufficien...

Страница 8: ...tes with any newly discovered devices Selecting devices for analysis can be done while recording Note The Capture Toolbar Analyze button will be grayed out until some wireless devices have been selected for analysis The Security pane will show all encrypted Bluetooth links The Event Log pane will begin to populate with information warnings and error messages The Status Bar will show a running tota...

Страница 9: ...he Set in Target hardware will begin sending captured packets involving the selected device to the Frontline software Once analysis has begun you cannot change the device selection All device rows in the Wireless Devices and Wired Devices pane are grayed out To stop the analysis click on the Analyzing button You can then change your device selection and restart analysis by clicking on the Analyze ...

Страница 10: ...Temperature 10 C to 40 C 14 F to 104 F l Power Input 12 VDC tip positive l Max Power 25 W l Battery NB2037FQ31 Caution There is a risk of explosion if the battery is replaced by an incorrect type Dispose of old batteries according to your local regulations Service Notes The Sodera hardware does not contain any user serviceable items Any repairs and maintenance must be performed by a service techni...

Страница 11: ...Frontline Technical Support Phone 1 434 984 4500 or email tech_support fte com Publish date 11 16 2016 ...

Отзывы: