U
SER
M
ANUAL
8
K
/4
K
CL
M
ONO
–
R
EV
I
–
06/2017
P
A G E
|
54
7.10
Save & Restore Settings
The settings (or Main configuration) of the Camera can be saved in 4 different User banks and one Integrator
bank. This setting includes also the FFC and LUT enable
This function is available in the Save & Restore Settings section :
Load settings from Bank :
Allows to restore the Camera settings.
Read function : “
r rcfg
” : Get the current Tap Bank in use
Write function : “
w rcfg <val>
” : Load settings from bank <val> (0: Factory , 1 to 4 for Users, 5 for
Integrator)
Save settings to Bank :
Allows to save the Camera settings in User or Integrator Bank
Write function : “
w scfg
<val>
” : Save the current settings in the User bank <val> (1 to 4 for User,
5 for Integrator)
The integrator bank (User Set5) can be written only if the Camera is set in integrator mode
(Privilege level = 1). This integrator bank can be used as a « Factory default » by a system
integrator
.
Configuration Bank Usage
At the power up :
Last User Bank used is loaded in RAM
“Integrator” Bank (5) can be locked by switching the Camera in “User” mode (cf : Privilege feature). Then it can’t
be saved any more without switching back the Camera in “Integrator” Mode.
7.10.1
Command Table
Feature
Commands
Description
UserSetLoad
r rcfg
Get the current user configuration bank (saved or restored)
w rcfg <val>
Restore current UserSet from UserSet bank number <val>, from 0
to 5; <val> comes from UserSetSelector.
UserSetSave
w scfg <val>
Save current UserSet to UserSet bank number <val>, from 1 to 5;
<val> comes from UserSetSelector. 0 cannot be saved. 5
(Integrator) can’t be saved in User mode
UserSetControl
Xml virtual
Ram Memory
Save
Load
Factory
Integrator
User1
User2
User3
User4
User
Load
Save