background image

Table of contents

10.5

Administration tab ................................................................... 30
10.5.1 Firewall ...................................................................... 30
10.5.2 SSL certificates ........................................................... 30
10.5.3 Services..................................................................... 30
10.5.4 Web protocols ............................................................. 31
10.5.5 User management........................................................ 31
10.5.6 Regional settings ......................................................... 31
10.5.7 Network settings .......................................................... 31
10.5.8 System and firmware .................................................... 32
10.5.9 SNMP settings............................................................. 33
10.5.10 Multicast settings ......................................................... 33

10.6

Settings tab ........................................................................... 33
10.6.1 General settings........................................................... 33
10.6.2 Alarm recipients ........................................................... 33
10.6.3 Scheduler................................................................... 34
10.6.4 MQTT........................................................................ 34
10.6.5 Modbus ..................................................................... 35

10.7

Library

tab............................................................................. 36

10.7.1 Managing images......................................................... 36
10.7.2 Managing videos.......................................................... 36
10.7.3 Managing logs............................................................. 36

11

Pin configurations ........................................................................... 37

11.1

Ethernet connector and cable .................................................... 37

11.2

Power/Digital I/O connector and cable ......................................... 39

11.3

RS232/RS485 connector .......................................................... 40

12

A-series connection board................................................................ 41

12.1

Connection examples .............................................................. 43

13

Software supported byFLIR A50/A70 series cameras........................... 49

14

Mechanical drawings ....................................................................... 50

15

EU Declaration of conformity ............................................................ 52

16

Indicator LEDs and factory reset button ............................................. 54

16.1

Power/error indicator LED and factory reset button ......................... 54

16.2

Power/error indicator LED and power modes ................................ 54

16.3

Wired Ethernet connection........................................................ 54

17

Cleaning the camera ........................................................................ 55

17.1

Camera housing, cables, and other items..................................... 55

17.2

Infrared lens .......................................................................... 55

18

About calibration............................................................................. 56

18.1

Introduction ........................................................................... 56

18.2

Definition—what is calibration? .................................................. 56

18.3

Camera calibration at FLIR Systems ........................................... 56

18.4

The differences between a calibration performed by a user and
that performed directly at FLIR Systems....................................... 57

18.5

Calibration, verification and adjustment........................................ 57

18.6

Non-uniformity correction.......................................................... 58

18.7

Thermal image adjustment (thermal tuning) .................................. 58

19

About FLIR Systems ........................................................................ 59

19.1

More than just an infrared camera .............................................. 60

19.2

Sharing our knowledge ............................................................ 60

19.3

Supporting our customers......................................................... 61

#T810579; r. AB/78918/78918; en-US

iv

Содержание 89829-0201

Страница 1: ...User s manual FLIR A50 A70 series Sie haben Fragen oder w nschen eine Beratung Angebotsanfrage unter 49 7121 51 50 50 oder ber info datatec eu Distributed by...

Страница 2: ...tos megjegyz s Az eszk z haszn lata el tt figyelmesen olvassa el s tartsa be az sszes utas t st figyelmeztet st vint zked st s jogi nyilatkozatot Nota importante Prima di utilizzare il dispositivo imp...

Страница 3: ...ition monitoring 10 5 1 4 Research development 11 6 Camera parts 12 7 Camera installation 13 8 Mechanical installation 14 9 RTSP Streams 15 10 Camera web interface 16 10 1 Supported browsers 16 10 2 L...

Страница 4: ...ftware supported byFLIR A50 A70 series cameras 49 14 Mechanical drawings 50 15 EU Declaration of conformity 52 16 Indicator LEDs and factory reset button 54 16 1 Power error indicator LED and factory...

Страница 5: ...face of the product 1 6 Usage statistics FLIR Systems reserves the right to gather anonymous usage statistics to help maintain and improve the quality of our software and services 1 7 Copyright 2021 F...

Страница 6: ...owing two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation WARNING Applicab...

Страница 7: ...or Air of lower quality than Process air can contain high levels of contaminants Damage to the detector can occur CAUTION Applicability Cameras with an automatic shutter that can be disabled Do not di...

Страница 8: ...3 3 Accuracy For very accurate results we recommend that you wait 5 minutes after you have started the camera before measuring a temperature 3 4 Disposal of electronic waste Electrical and electronic...

Страница 9: ...prod ucts as well as manuals for our historical and obsolete products 3 7 Important note about this manual FLIR Systems issues generic manuals that cover several cameras within a model line This means...

Страница 10: ...l The camera serial number The communication protocol or method between the camera and your device e g SD card reader HDMI Ethernet USB or FireWire Device type PC Mac iPhone iPad Android device etc Ve...

Страница 11: ...API to transfer data from the cam era to a web interface or to an application on the internet The Image Streaming cameras deliver images with all related information to a com puter where the user can...

Страница 12: ...Sensor camera 3 Ethernet connector X coded 4 Power I O connector A coded 5 Digital output to a programmable logic controller PLC 6 Separate DIN rail power supply for galvanic isolation 18 56 V DC 7 L...

Страница 13: ...ing custom made software 2 CAT 6 Ethernet cables 3 Industrial Power over Ethernet PoE switches with fiber optic posts 4 Fiber optic cable 5 FLIR A50 A70 Image Streaming cameras 6 Industrial process to...

Страница 14: ...critical assets 1 Computer running custom made software 2 CAT 6 Ethernet cable 3 Industrial power over Ethernet PoE switch 4 FLIR A50 A70 Image Streaming cameras 5 Industrial process to be monitored e...

Страница 15: ...heat dissipation on PCB during development 1 Computer running FLIR science software e g FLIR Research Studio 2 CAT 6 Ethernet cable 3 Laboratory setup with a FLIR A50 A70 Advanced Image Streaming cam...

Страница 16: ...For details see section 16 Indicator LEDs and factory reset button page 54 2 Ethernet communication indicator LED green 3 Antenna 4 Power I O connector A coded 5 Factory reset button 6 RS232 485 conne...

Страница 17: ...the power cable between the camera and a power source for pin config urations refer to the user manual of the FLIR A50 A70 series Connect the net work cable to the camera and then either directly to t...

Страница 18: ...ounted on a bracket or heat sink made of a material with a high capacity to transfer heat e g aluminum The use of a cooling bracket or a heat sink is also strongly recommended in order to minimize the...

Страница 19: ...ding mpeg4 MPEG4 encoding mjpg Motion JPEG encoding The section after the encoding refers to the source which can be either or ch1 will start a streaming session giving you the identical video as seen...

Страница 20: ...ogging in for the first time log in with the username admin and the default ad ministrator password provided by FLIR available on the camera calibration certificate Note The users viewer and user are...

Страница 21: ...t tools are labeled with a number for identification ac cording to the order of their creation Added measurement tools show up in the Active measurements section where the they can be managed and wher...

Страница 22: ...re scale page 28 5 4 To display how much of the tool is covered by an isotherm select the Iso check box This setting is only applicable if you have selected a color alarm isotherm For more information...

Страница 23: ...draw the line to the desired length The tool is labeled with a number and it is also displayed in the Active measurements section 3 To move the tool click and hold the tool label in the image and the...

Страница 24: ...ement 10 4 1 6 Delta Use the delta measurement tool to calculate the difference between two measurement results or between a measurement result and a fixed temperature reference temperature To add a d...

Страница 25: ...a change in the trigger If the threshold is set above 30 0 C and the hystere sis is set at 2 0 C the trigger goes high when the temperature rises above 30 0 C and stays high until the temperature drop...

Страница 26: ...was triggered 5 When completed click Set alarm The alarm is now listed under Active alarms 10 4 2 3 Setting an alarm based on sensor temperature The internal temperature sensor can act as a thermomet...

Страница 27: ...bject emits compared with the radiation of a theoretical reference object at the same temperature called a blackbody The opposite of emissivity is reflectivity The emissivity determines how much of th...

Страница 28: ...ction click Settings next to the tool for which you want to change the parameters The Settings dialog box appears 2 To activate the use of local parameters select the Local parameters check box The va...

Страница 29: ...es within an image A different palette can make it easier to analyze the image The most suitable palette for a certain application depends on many different factors such as the target temperature and...

Страница 30: ...the Active measurements section Also a temperature indicator is added to the left side of the temperature scale lo cated to the right of the image 4 To change the threshold temperature click Settings...

Страница 31: ...be carried out automatically with different selectable intervals It is also possible to perform a cali bration manually 10 4 7 1 Automatic calibration To set the automatic calibration follow this pro...

Страница 32: ...ier to analyze details in the image For example by manually changing the maximum and or minimum temperature levels to levels near a certain object in the image you can study temperature variations in...

Страница 33: ...tream To pause or freeze the live image stream follow this procedure 1 On the toolbar and in the View modes section click Freeze 2 To resume the live image stream click Unfreeze 10 4 15 Hiding the ove...

Страница 34: ...the camera administrator can approve the client Approved clients can be revoked later on Temporarily enable the Auto approve functionality while setting up the network clients However it is recommend...

Страница 35: ...Server address box 2 Set date and time manually Select the correct Time zone in the list and then type date and time information in the Year Month Day Hour Minute and Second boxes 3 Get date and time...

Страница 36: ...Connect 10 5 7 3 Streaming bit rate Follow this procedure 1 In the navigation pane click Network settings 2 In the Streaming bit rate list select one of the available bit rates 3 Click Apply 10 5 8 S...

Страница 37: ...he Device label box Select the Display in status bar check box to show the camera ID on the active tab of the web browser and in the upper part of saved images 10 6 1 2 Test Digital Input Output Use t...

Страница 38: ...w this procedure 1 In the FTP Server box type the IP address of the FTP server 2 In the FTP User and FTP Password boxes type the credentials for the FTP access 3 Click Apply To configure delivery by e...

Страница 39: ...hen setting up alarms see section 10 4 2 Working with alarms page 20 10 6 5 2 Analogue out The camera has no analogue outputs but by using the built in Modbus master function ality and an analogue out...

Страница 40: ...k Preview 3 To download an image click the image file name and then click Download 4 To delete one or more images click the image file name s and then click Delete 10 7 2 Managing videos To manage vid...

Страница 41: ...Pin configurations 11 11 1 Ethernet connector and cable Figure 11 1 Female X coded M12 Ethernet connector Pin Configuration 1 DA 2 DA 3 DB 4 DB 5 DD 6 DD 7 DC 8 DC T810579 r AB 78918 78918 en US 37...

Страница 42: ...Pin configurations 11 Figure 11 2 Ethernet cable M12 to RJ45 T810579 r AB 78918 78918 en US 38...

Страница 43: ...nd cable Figure 11 3 Male A coded M12 Power Digital I O connector Pin Configuration 1 EXTPWR_RTN 2 EXTPWR_IN 3 FAULT_A 4 FAULT_B 5 DIGOUT1A 6 DIGOUT1B 7 DIGOUT2A 8 DIGOUT2B 9 DIGIN1 10 DIGIN2 11 Not C...

Страница 44: ...3 Green 4 Purple 5 Yellow 6 Pink 7 Orange 8 Brown 9 White 10 Grey 11 Light blue 12 Blue 11 3 RS232 RS485 connector Figure 11 5 Male A coded M8 RS232 RS485 connector Pin Configuration 1 RS232_TXD alt R...

Страница 45: ...onnection board is an accessory that can be used to test functionality and digital connections to from the camera Figure 12 1 A series connection board For schematics and connection examples see the n...

Страница 46: ...A GROUND A B A B 10k 10k DIGIN_1 DIGIN_2 DIGIN_GND DIGIN_1 DIGIN_2 DIGIN_GND FUSE FUSE INDICATOR INDICATOR DIGITAL GROUND TEST DIGIN_1 CAMERA POWER INPUT DIGITAL POWER INPUT DIGITAL OUTPUTS DIGITAL IN...

Страница 47: ...A series connection board 12 12 1 Connection examples See next page T810579 r AB 78918 78918 en US 43...

Страница 48: ...GIN_2 DIGIN_GND DIGIN_1 DIGIN_2 DIGIN_GND DIGITAL GROUND TEST DIGIN_1 DIGITAL INPUTS TEST DIGIN_2 3 VOLT DROP 3 VOLT DROP JUMPER JUMPER JUMPER DIGITAL POWER 12V REG DIGITAL POWER DIGITAL GROUND TEST D...

Страница 49: ...DIGOUT_1A DIGOUT_1B DIGOUT_2A DIGOUT_2B FAULT_A FAULT_B DIGITAL POWER DIGITAL GROUND A B DIGITAL GROUND DIGITAL POWER A B A B 10k 10k DIGITAL OUTPUTS JUMPER JUMPER JUMPER 1 2 3 1 2 3 1 2 3 1 2 3 TEST...

Страница 50: ..._A FAULT_B DIGOUT_1A DIGOUT_1B DIGOUT_2A DIGOUT_2B FAULT_A FAULT_B DIGITAL POWER DIGITAL GROUND A B DIGITAL GROUND DIGITAL POWER A B A B 10k 10k DIGITAL OUTPUTS JUMPER JUMPER JUMPER 1 2 3 1 2 3 1 2 3...

Страница 51: ...GOUT_2A DIGOUT_2B FAULT_A FAULT_B DIGITAL POWER DIGITAL GROUND A B DIGITAL GROUND DIGITAL POWER A B A B 10k 10k DIGITAL OUTPUTS JUMPER JUMPER JUMPER 1 2 3 1 2 3 1 2 3 1 2 3 Vin Voltage Input Device DI...

Страница 52: ...OUND 18 30V 0V CAMERA POWER CAMERA GROUND CAMERA POWER CAMERA GROUND DIGITAL GROUND CAMERA GROUND FUSE FUSE INDICATOR INDICATOR CAMERA POWER INPUT DIGITAL POWER INPUT JUMPER JUMPER 18 30V 0V TEST Exte...

Страница 53: ...upported byFLIR A50 A70 series cameras 13 For a list of supported software see the online documentation for the FLIR A50 A70 camera series http support flir com resources 9s26 T810579 r AB 78918 78918...

Страница 54: ...Mechanical drawings 14 See next page T810579 r AB 78918 78918 en US 50...

Страница 55: ...ICOIL 8mm 0 31in IR Lens 29 deg IR Lens 51 deg Generic dimensions for all FOV 1 2 3 4 5 6 7 8 9 10 1 6 3 2 5 4 A B C D E F G H F C E G D A B Scale 1 1 A Rev Modified R D JOHE Basic dimension Ax0 T1312...

Страница 56: ...EU Declaration of conformity 15 See next page T810579 r AB 78918 78918 en US 52...

Страница 57: ...Union harmonisation legislation Directives Directive 2011 65 EU RoHS and 2015 830 EU Phtalates Directive 2014 53 EU Radio Equipment Directive RED Standards Emission EN 55032 2015 Electromagnetic Comp...

Страница 58: ...a s IP settings are reset to the fac tory defaults DHCP assigned The indicator LED status resumes the status it had before the button was depressed 10 seconds A rapidly flashing red light When the fac...

Страница 59: ...it must be dry Do not use a lens cleaning cloth with the liquids that are listed above These liquids can cause material on the lens cleaning cloth to become loose This material can have an unwanted e...

Страница 60: ...lishes the relation between emitted radiation the quantity value and the electrical output signal the indication This first step of the calibration procedure consists of obtaining a homo geneous or un...

Страница 61: ...rs All FLIR Systems cameras are drift compensated when they are first delivered to the customer and when they are recalibrated by FLIR Systems serv ice departments 18 5 Calibration verification and ad...

Страница 62: ...al situation they should all give the same output sig nal However each individual element has its own response so the output is not uniform This deviation from the ideal result is calculated and used...

Страница 63: ...s acquired several companies with world leading expertise NEOS 2019 Endeavor Robotics 2019 Aeryon Labs 2019 Seapilot 2018 Acyclica 2018 Prox Dynamics 2016 Point Grey Research 2016 DVTEL 2015 DigitalOp...

Страница 64: ...tem elec tronics to final testing and calibration all production steps are carried out and supervised by our own engineers The in depth expertise of these infrared specialists en sures the accuracy an...

Страница 65: ...ms operates a worldwide service network to keep your camera running at all times If you discover a problem with your camera local service centers have all the equipment and expertise to solve it withi...

Страница 66: ...served worldwide Disclaimer Specifications subject to change without further notice Models and accessories subject to regional market considerations License procedures may apply Products described her...