4. Browse to the location of the firmware file, select the file, and then click
Open
.
5. Click
Upgrade firmware
.
6. When the upgrade is completed, restart the camera.
10.5.9
SNMP settings
Use the
SNMP settings
page to enable and disable Simple Network Management Proto-
col (SNMP). When enabled, type the IP address of your device, and the port and interval
time.
10.5.10
Multicast settings
Use the
Multicast settings
page to manage the settings for multicast communication,
which can be used when multiple clients are using the camera video stream. Settings
can be changed for each of the two video streams; IR and Visual/Digital Camera.
10.6
Settings tab
Note
The
Settings
tab is only available for the
admin
and
user
roles.
Under the
Settings
tab you can manage:
• General settings
• Alarm recipients
• Scheduler
• MQTT
• Modbus
10.6.1
General settings
The
General settings
page displays
Product
information,
Camera ID
,
IP6x settings
, and
the possibility to
Test Digital Input/Output
functionality.
10.6.1.1
Camera ID
Type the preferred camera ID in the
Device label
box. Select the
Display in status bar
check box to show the camera ID on the active tab of the web browser and in the upper
part of saved images.
10.6.1.2
Test Digital Input/Output
Use the test buttons to the test the electrical interfaces of the camera and the communi-
cation with them. These tests are useful when you set up the interfaces.
Click
Test (5s)
. A successful test is indicated by a green “dot” for 5 seconds.
10.6.2
Alarm recipients
Use the
Alarm recipients
page to configure alarm notifications. Notifications can be sent
by e-mail or to a folder on an FTP server.
To configure delivery by e-mail, follow this procedure:
1. In the navigation pane, click
Alarm recipients
.
2. In the
Alarm recipient e-mail
box, type the e-mail address of the recipient.
3. In the
Mail server setup
box, type the IP address of the sending mail server.
4. If the sending mail server requires a login (mail server authentication), select the
Au-
thentication required
check box, and then type the credentials in the
User
and
Pass-
word
boxes.
5. Click
Apply
.
To configure delivery to FTP, follow this procedure:
1. In the navigation pane, click
Alarm recipients
.
2. In the
FTP Server IP address
box, type the IP address of the FTP server.
#T810579; r. AB/78918/78918; en-US
33
Содержание 89829-0201
Страница 42: ...Pin configurations 11 Figure 11 2 Ethernet cable M12 to RJ45 T810579 r AB 78918 78918 en US 38...
Страница 47: ...A series connection board 12 12 1 Connection examples See next page T810579 r AB 78918 78918 en US 43...
Страница 54: ...Mechanical drawings 14 See next page T810579 r AB 78918 78918 en US 50...
Страница 56: ...EU Declaration of conformity 15 See next page T810579 r AB 78918 78918 en US 52...