4220 Flow Meter
Section 1 Introduction
1-8
1.6 Technical
Specifications
The technical specifications for the 4220 Flow Meter are found in
Table 1-2. The anticipated longevity for a roll of paper used in the
internal plotter is shown for various chart speeds in Table 1-4.
Battery life expectancy is found in Table 1-5.
Table 1-2 Technical Specifications for the 4220 Flow Meter
Physical Specifications
Size 16"
high
×
11
1
⁄
2
"
wide
×
10
1
⁄
2
"
deep (40.6
×
29.2
×
26.7 cm) (without
power source attached).
Weight
17 lb. 4 oz. (7.7 kg)
Material
High-impact molded polystyrene structural foam.
Type
Self-certified NEMA 4X Enclosure.
Display Type
2-line, 40 character/line alphanumeric dot matrix liquid crystal.
Power
12 -14 VDC, 16 mA average at 12.5 VDC (Plotter set at 1" per hour).
Typical Battery Life
7-10 days with plotter at 1" per hour and 4 Ampere-hour Ni-Cad bat-
tery.
14 days with plotter turned
off
.
Operating Temperature
0° to 140°F (–18° to 60°C).
Storage Temperature
–40° to 158°F (–40° to 70°C).
Additional Power Required
for Optional Equipment
Modem
60 mA maximum during operation; 0.1 mA maximum standby.
High-Low Alarm Relay Box
10 mA standby, typical; 190 mA - both relays operated.
Internal Printer
Chart Speeds
Off,
1
⁄
2
, 1, 2, or 4 inches per hour.
Ribbon
19.7 ft. (6 m) black nylon - replaceable.
Operating Speed
1.5 lines per second at 68° F. (20°
C).
Character Size
0.09" high
×
0.07" wide (2.4mm
×
1.7 mm), 12 pitch.
Printer Recording Span
Chart Resolution
Display Resolution
User-selected from
1
⁄
4
ft. (3.6 cm) to over 30 ft. (9.1 m) with multiple
over-ranges.
1
⁄
240
of selected recording span
0.001 ft. (0.3 mm)
Paper 4.5"
wide
×
65 ft. (11.4 cm
×
19.8 m) plain white paper, replaceable.
Printer Reliability
2.5 million lines MCBF (mean cycles before failure).
Reports Printed
Program selections, interval activity reports, flow meter history.
Printer Recording Modes
Level, flow rate; includes totalized flow, sampler events, rainfall, tem-
perature, velocity, pH (or) D. O. (dissolved oxygen).
Plotted Linear Data
3 different linear plots can be printed at the same time.
Содержание 4220
Страница 2: ......
Страница 4: ......
Страница 8: ...4220 Flow Meter Safety ...
Страница 14: ...vi ...
Страница 19: ...4220 Flow Meter Section 1 Introduction 1 5 Figure 1 2 4220 Controls and Indicators ...
Страница 28: ...4220 Flow Meter Section 1 Introduction 1 14 ...
Страница 94: ...4220 Flow Meter Section 3 Installation 3 12 ...
Страница 156: ...4220 Flow Meter Appendix A Replacement Parts A 2 ...
Страница 157: ...4220 Flow Meter Appendix A Replacement Parts A 3 ...
Страница 160: ...4220 Flow Meter Appendix A Replacement Parts A 6 ...
Страница 164: ...4220 Flow Meter Appendix B Accessories List B 4 ...
Страница 172: ...4220 Flow Meter Appendix C Programming Worksheets C 8 ...
Страница 182: ...4220 Flow Meter Appendix D General Safety Procedures D 10 ...
Страница 194: ......
Страница 196: ...Warranty ...
Страница 198: ......