![Teledyne TapTone T4000 APX Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/teledyne-taptone/t4000-apx/t4000-apx_installation-manual_1081094046.webp)
M-412-064 Chapter 3: Installation Instructions
TELEDYNE TAPTONE
39
3.7.5 Reject Acknowledge Sensor Setup
1. Mount your reject acknowledge sensor at the opening to the reject station. The sensor
should be blocked as the container enters the reject station. Make sure the rejected
container does not bounce back and block the reject sensor.
2. Connect the reject sensor to Input #1 of the I/O Board.
3. Go to the Reject Acknowledge On/Off menu in Rejector #1 menu. Turn the reject
acknowledge function On.
4. Go to the Reject Acknowledge Distance menu in Rejector #1 menu. Press the force
reject button to reject the next container. Note the Measured Distance value then set
the Reject Sensor Distance to be the same as the Measured Distance. Repeat
several times to ensure the proper distance value is set.
5. Connect any of the four PLC output modules to the conveyor stop, lamp or alarm
signal that will identify a missed reject. Select reject acknowledge function for the
desired PLC output. When the output is activated press the ENTER key to clear the
alarm condition.
3.7.6 Trigger Sensor Setup
1. Output Selection Switch
– This switch controls the output operation for the sensor. Set
the output selection switch to the D.O. (Dark Operate) position. This means the output
of the sensor will go high when the beam is blocked. Make sure the switch is all the
way to the D.O. position stop. Use care when adjusting this control, as the stop can
break if turned too far.
2. Output LED
– When the sensor beam is free, this LED will continuously flicker to
indicate the photo beam gain adjustment. The LED will turn off when the beam is
blocked or if the gain is set too low.
3. Gain Adjust
– This 15 turn potentiometer is adjusted clockwise (CW) to increase the
photo beam receive gain. Adjust counter clockwise (CCW) to reduce the receive gain.
To set the gain, rotate CCW until the LED turns off, then rotate CW just until the LED
comes ON. Once the LED lights, adjust the gain two full rotations CW.
Содержание T4000 APX
Страница 1: ...TapTone T4000 APX Installation Manual M 412 073 Rev B...
Страница 2: ...This page left blank...
Страница 4: ...This page left blank...
Страница 17: ...M 412 073 Chapter 3 Installation Instructions TELEDYNE TAPTONE 10 3 1 3 Proximity Configuration T4000 P...
Страница 19: ...M 412 073 Chapter 3 Installation Instructions TELEDYNE TAPTONE 12 3 1 5 X ray Configuration T4000 X...
Страница 20: ...M 412 073 Chapter 3 Installation Instructions TELEDYNE TAPTONE 13 3 1 6 Acoustic X ray Configuration T4000 AX...
Страница 21: ...M 412 073 Chapter 3 Installation Instructions TELEDYNE TAPTONE 14 3 1 7 Proximity X ray Configuration T4000 PX...
Страница 52: ...M 412 073 Appendix C X Ray Safety Survey Plot TELEDYNE TAPTONE 45 Appendix C X Ray Safety Survey Plot B 412 119...
Страница 53: ...M 412 073 Appendix C X Ray Safety Survey Plot TELEDYNE TAPTONE 46...
Страница 54: ...M 412 073 Appendix C X Ray Safety Survey Plot TELEDYNE TAPTONE 47...