background image

PP026 Passive Probe 

EC Declaration of Conformity 

The probe is marked with this symbol to show compliance was 

demonstrated to the specifications listed in the Official Journal of 

the European Communities: Low Voltage Directive 2006/95/EC: 

EN 61010-031/A1:2008 Safety requirements for electrical equipment for 

measurement, control and laboratory use – Part 031: Safety requirements 

for handheld probe assemblies for electrical measurement and test. 

EU RoHS Compliance 

The probe and its accessories conform to the 2011/65/EU RoHS2 Directive, 

as they have been classified as Industrial Monitoring and Control 

Equipment (per Article 3, Paragraph 24) and are exempt from RoHS 

compliance until 22 July 2017 (per Article 4, Paragraph 3). 

General Safety Information 

Observe generally accepted safety procedures in addition to those 

listed here to avoid personal injury or damage to equipment. The 

overall safety of any system incorporating this accessory is the 

responsibility of the assembler of the system. 
Connect only to grounded instruments. Use only with compatible Teledyne 

LeCroy oscilloscopes that have their BNC input connected to an earth 

ground. Do not connect the probe reference lead to any point which is at a 

potential other than earth ground. 
Connect and disconnect properly. Connect probe to the oscilloscope before 

connecting it to the test circuit. Disconnect the probe input and reference 

lead from the test circuit before disconnecting from the oscilloscope. Do 

not connect or disconnect probes while they are connected to a voltage 

source. 

Содержание PP026 Series

Страница 1: ...PP026 1 PP026 2 Operator s Manual PP026 Passive Probe...

Страница 2: ...roy is a registered trademark of Teledyne LeCroy Inc Other product or brand names are trademarks or requested trademarks of their respective holders Information in this publication supersedes all earl...

Страница 3: ...OTECTIVE EARTH TERMINAL Introduction The Teledyne LeCroy PP026 is a passive high impedance voltage oscilloscope probe designed and calibrated for use with general purpose oscilloscopes having an input...

Страница 4: ...o 30 C 5 to 75 RH 30 C to 40 C 5 to 50 RH above 40 C RH not controlled below 10 C Operating Altitude 3000 meters maximum To reduce risk of fire or electric shock do not exceed the voltage or category...

Страница 5: ...Operator s Manual 3 PP026 Input Impedance Profile Voltage vs Frequency Derating Curve...

Страница 6: ...iance until 22 July 2017 per Article 4 Paragraph 3 General Safety Information Observe generally accepted safety procedures in addition to those listed here to avoid personal injury or damage to equipm...

Страница 7: ...or cause other bodily injury if not handled properly Keep fingers behind the finger guard of probe body and accessories Do not operate with suspected failures Before each use inspect the probe and acc...

Страница 8: ...n oscilloscopes Low Frequency 1 Apply a 1 kHz square wave to the probe or connect to the oscilloscope s calibrator output 2 Adjust the single LF trimmer located on the PP026 BNC Box until you achieve...

Страница 9: ...compensated correct and under compensated waveforms Service Refer all service to qualified personnel For the most complete and up to date list of sales and service centers by country visit teledynele...

Страница 10: ...PK5 PK6 002 Color Coding Rings 2 ea yellow red green blue 8 5 PK6 5MM 103 Ground Lead with Alligator Clip 1 6 PK6 5MM 104 Ground Spring 1 7 PK6 5MM 105 PCB Adapter 1 8 PK6 5MM 106 BNC Adapter 5mm 1 9...

Страница 11: ...oy at its option will either repair or replace any assembly returned within the warranty period to the Customer Service Department of an authorized service center However this will be done only if the...

Страница 12: ...925647 00 May 2015...