AP031 Probe 

923064-00 Rev A 

Specifications 

Electrical Characteristics 

Bandwidth 

25 MHz 

Rise Time 

14 ns 

Attenuation 

1:10 / 1:100 

Atten. Accuracy 

±2 %

 

Input Resistance 

4 MΩ 

Input Capacitance 

5.5 pF each side to ground 

Input Configuration 

Differential

 

Input Voltage 

Max. Differential 1:100 Range

 

±700 V (DC + AC pk) and 700 V r.m.s. 

 

Max. Differential 1:10 Range

 

±70 V (DC + AC pk) and 70 V r.m.s. 

 

Max. Common Mode

 

±700 V ( DC + AC pk) and 700 V r.m.s. 

 

Max. Absolute 

±1400 V ( DC + AC pk) and 1000 V r.m.s. 

CMRR 

 

50 Hz

   - 80 dB 

 

 

20 kHz

   - 60 dB 

Output Offset (Typical) 

<±5 mV 

Output Noise (Typical) 

0.7 mV r.m.s typical 

www.

.com

[email protected]

1.800.561.8187

Содержание AP031

Страница 1: ...Operator s Manual AP031 Differential Probe www com information itm com 1 800 561 8187...

Страница 2: ...90 days In exercising its warranty Teledyne Lecroy at its option will either repair or replace any assembly returned within its warranty period to the Customer Service Department or an authorized ser...

Страница 3: ...mbols These symbols may appear on the probe body or in this manual to alert you to important safety considerations HIGH VOLTAGE risk of electric shock CAUTION of potential for damage to probe or instr...

Страница 4: ...obe hooks to a votage source unless they are first connected to the probe input leads Ensure connections between probe input leads and probe hooks are secure before connecting them to a voltage source...

Страница 5: ...relative to a floating voltage different to the oscilloscope ground potential This probe is specifically designed for situations where The reference voltage may be several hundreds volts above or bel...

Страница 6: ...is calculated within the probe with only the resultant difference signal being passed to the oscilloscope a large dynamic range can be achieved with excellent rejection of common mode signals Figure 1...

Страница 7: ...round Input Configuration Differential Input Voltage Max Differential 1 100 Range 700 V DC AC pk and 700 V r m s Max Differential 1 10 Range 70 V DC AC pk and 70 V r m s Max Common Mode 700 V DC AC pk...

Страница 8: ...be expected General Characteristics Operating Temperature 10 C to 40 C Storage Temperature 30 C to 70 C Altitude Operating up to 2000 m 6560 ft Cable Length 1 3 m Weight probe only 42 g Power require...

Страница 9: ...injury to the user from possible burns at higher frequencies WARNING To avoid risk of electric shock or fire do not exceed either the voltage rating or category rating of the probe or the probe hook w...

Страница 10: ...oscilloscope channel to which the probe is connected using the Probe tab of the Channel Vertical setup dialog Ensure 1 M input impedance DC1M or AC1M is selected The use of 50 input impedance will un...

Страница 11: ...e probes must be returned to a Teledyne LeCroy service facility for diagnosis and exchange A defective probe under warranty will be replaced with a factory refurbished probe A probe that is not under...

Страница 12: ...Radiated and Conducted Emissions Group 1 Class A 1 2 Electromagnetic Immunity EN 61000 4 2 2001 Electrostatic Discharge 4 kV contact 8 kV air 4 kV vertical horizontal coupling planes 3 EN 61000 4 3 2...

Страница 13: ...ions Act per the following standards in accordance with requirements imposed by Australian Communication and Media Authority ACMA CISPR 11 2003 Radiated and Conducted Emissions Group 1 Class A in acco...

Страница 14: ...and laboratory use Part 2 030 Particular requirements for testing and measuring circuits EN 61010 031 A1 2008 Safety requirements for electrical equipment for measurement control and laboratory use Pa...

Страница 15: ...disposal and recycling regulations that vary by country and region Many countries prohibit the disposal of waste electronic equipment in standard waste receptacles For more information about proper d...

Отзывы: