This section certifies the AP031 probe’s Electromagnetic Compatibility (EMC), Safety and 
Environmental compliances. 

EMC Compliance 

EC Declaration of Conformity - EMC 

The probe meets intent of EC Directive 2004/108/EC for Electromagnetic Compatibility. 
Compliance was demonstrated to the following specifications as listed in the Official Journal 
of the European Communities: 
EN 61326-1:2006, EN 61326-2-1:2006 EMC requirements for electrical equipment for 
measurement, control, and laboratory use. 

 

Electromagnetic Emissions: 

CISPR 11:2003, Radiated and Conducted Emissions Group 1, Class A 

1 2 

 

Electromagnetic Immunity: 

EN 61000-4-2:2001 Electrostatic Discharge, 4 kV contact, 8 kV air, 4 kV vertical/horizontal 
coupling planes 

3

 

EN 61000-4-3:2006 RF Radiated Electromagnetic Field, 3 V/m, 80-1000 MHz; 3 V/m, 1400 
MHz - 2 GHz; 1 V/m, 2 GHz - 2.7 GHz 

3

 

1 Emissions which exceed the levels required by this standard may occur when the probe is connected to a test 
object. 
2 This product is intended for use in nonresidential areas only. Use in residential areas may cause electromagnetic 
interference. 
3 Meets Performance Criteria “B” limits of the respective standard: during the disturbance, product undergoes a 
temporary degradation or loss of function or performance which is self-recoverable. 

www.

.com

[email protected]

1.800.561.8187

Содержание AP031

Страница 1: ...Operator s Manual AP031 Differential Probe www com information itm com 1 800 561 8187...

Страница 2: ...90 days In exercising its warranty Teledyne Lecroy at its option will either repair or replace any assembly returned within its warranty period to the Customer Service Department or an authorized ser...

Страница 3: ...mbols These symbols may appear on the probe body or in this manual to alert you to important safety considerations HIGH VOLTAGE risk of electric shock CAUTION of potential for damage to probe or instr...

Страница 4: ...obe hooks to a votage source unless they are first connected to the probe input leads Ensure connections between probe input leads and probe hooks are secure before connecting them to a voltage source...

Страница 5: ...relative to a floating voltage different to the oscilloscope ground potential This probe is specifically designed for situations where The reference voltage may be several hundreds volts above or bel...

Страница 6: ...is calculated within the probe with only the resultant difference signal being passed to the oscilloscope a large dynamic range can be achieved with excellent rejection of common mode signals Figure 1...

Страница 7: ...round Input Configuration Differential Input Voltage Max Differential 1 100 Range 700 V DC AC pk and 700 V r m s Max Differential 1 10 Range 70 V DC AC pk and 70 V r m s Max Common Mode 700 V DC AC pk...

Страница 8: ...be expected General Characteristics Operating Temperature 10 C to 40 C Storage Temperature 30 C to 70 C Altitude Operating up to 2000 m 6560 ft Cable Length 1 3 m Weight probe only 42 g Power require...

Страница 9: ...injury to the user from possible burns at higher frequencies WARNING To avoid risk of electric shock or fire do not exceed either the voltage rating or category rating of the probe or the probe hook w...

Страница 10: ...oscilloscope channel to which the probe is connected using the Probe tab of the Channel Vertical setup dialog Ensure 1 M input impedance DC1M or AC1M is selected The use of 50 input impedance will un...

Страница 11: ...e probes must be returned to a Teledyne LeCroy service facility for diagnosis and exchange A defective probe under warranty will be replaced with a factory refurbished probe A probe that is not under...

Страница 12: ...Radiated and Conducted Emissions Group 1 Class A 1 2 Electromagnetic Immunity EN 61000 4 2 2001 Electrostatic Discharge 4 kV contact 8 kV air 4 kV vertical horizontal coupling planes 3 EN 61000 4 3 2...

Страница 13: ...ions Act per the following standards in accordance with requirements imposed by Australian Communication and Media Authority ACMA CISPR 11 2003 Radiated and Conducted Emissions Group 1 Class A in acco...

Страница 14: ...and laboratory use Part 2 030 Particular requirements for testing and measuring circuits EN 61010 031 A1 2008 Safety requirements for electrical equipment for measurement control and laboratory use Pa...

Страница 15: ...disposal and recycling regulations that vary by country and region Many countries prohibit the disposal of waste electronic equipment in standard waste receptacles For more information about proper d...

Отзывы: