Distributor of Teledyne LeCroy: Excellent Integrated System Limited
Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015
Contact us: [email protected] Website: www.integrated-circuit.com
Operator’s Manual
922254-00 Rev A
5
Table 1. List of Required Equipment
Description
Minimum Requirements
Test Equipment Examples
Wide Band oscilloscope
Minimum 200 MHz bandwidth
ProBus interface equipped
Software Version 7.6.0 or
greater
Teledyne LeCroy LT322
Teledyne LeCroy X-Stream
scope with AP-1M Hi-Z
adapter
Digital Multimeter
(2 required)
DC: 0.1% accuracy 5.5 digit
resolution with Null capability
(referenced measurements)
Agilent Technologies 34401A
Fluke 8842A-09
Keithley 2001
Leveled Sine Wave
Generator
Relative output level accurate
to ±0.3 dB into 50
Ω
1 to 100 MHz frequency
range Output adjustable to 18
dBm
Tegam SG503 with TM
series mainframe and
matching output cable.
A semiautomatic software
leveled signal source
calibrated with a power
meter may be substituted.
DC Power Supply
Output adjustable to > 6 V at
1 A
Agilent Technologies
E3610A
Calibration Fixture,
50 Turn Loop
50 Turn loop in series with 0.5
Ω ±0.2% resistor with sense
terminals
Teledyne LeCroy CP015-
CF02
Calibration Fixture,
High Speed Shunt
50
Ω Termination into single
turn loop.
VSWR < 1.25: 1 DC
– 50
MHz
Teledyne LeCroy CP015-
CF01
Calibration Fixture
ProBus Extension Cable
Teledyne LeCroy PROBUS-
CF01
BNC Adapter, T
Male-to-Dual-Female
Pomona 3285
BNC coaxial cable
Male-Male BNC, 50
Ω, 36”
Pomona 5697-36
Banana Plug adapter
BNC Female-to-Banana Plug Pomona 1269
Patch Cables
(4 required)
Male Banana-to-Male
Banana, 12”
Pomona B-12-0 (black)
Pomona B-12-2 (red)
10 / 25
10 / 25