2.4 CABLING AND TERMINATING METHODS
2.4.1
General
Stations and other ancillary equipment will normally be cabled direct to the S.D.F. The main
equipment is connected to the S.D.F. via cables terminated, at the main equipment end, on 50
pin AMP Champ connectors.
Twisted two-pair cabling must be used when installing these systems. FLAT UNDER CARPET
CABLE MUST NOT BE USED.
2.4.2
AMP Champ Connectors
=1
FIGURE 43 AMP CHAMP CONNECTOR -CABLE TERMINATION
Cables should be terminated in the following order, pair one located on pins number 1 and 26,
with the
on pin 1 and the mate on pin 26. Note the cable entry shown in figure 43.
To avoid damaging the conductors, the correct terminating
must be used. Brackets are
provided with the main equipment to retain the AMP Champ connectors in position on the main
equipment.
ISSUE 1