8

- Reception frequency   

 

 

868,3 MHz 

TVPLT868C80T0, TVPLT868C80TS

 

 

 

 

 

 

916 MHz 

TVPLT916C80T0, TVPLT916C80TS

- Power supply  

 

 

 

230Vac

- Max. power of the motor 

 

 

350W

- Default working time   

 

 

90 sec.

- Power of transformer  

 

 

80W - 24Vdc

- Maximum power of LED output 

 

70W - 24Vdc

- Operating temperature range  

        

-20° - +45°C

- Rain sensor power supply 

 

 

12 Vdc  max. 100mA

- Max. number of transmitters   

        

16

8.1 Technical specifications of the control unit

8.2 Technical specifications of the box

- Protection    

 

 

IP54

- Material of the box and its cover 

Thermoplastic ABS

- Colour of the box and its cover 

Grey RAL 7035

- Cable glands  

 

 

M16 (POLIAMMIDE 6.6)

- Sealing ring of cable glands   

NEOPRENE®

- Self-extinguishing class 

 

V2 (UL-94)

Not suitable for direct UV exposure

Teleco Automation S.r.l.

Italy
Tel. +39.0438.388511

Fax +39.0438.388536

[email protected]

Teleco Automation France

France
Tel. +33.(0)472.145080

Fax +33.(0)472.140503

[email protected]

Teleco Automation GmbH

Germany
Tel. +49.(0)8122.9563024

Fax +49.(0)8122.9563026

[email protected]

www.telecoautomation.com

Teleco Automation Oceania Pty Ltd

Australia
Tel. +61.(07)5502.7801

[email protected]

56 mm

151 mm

185 mm

70 mm

56 mm

18 mm

Product fastening holes 

Содержание TVPLT868C80T0

Страница 1: ...orization of single or double radio channels and 7 channels transmitters 1 TELECO AUTOMATION SRL Via dell Artigianato 16 31014 Colle Umberto TV ITALY TELEPHONE 39 0438 388511 FAX 39 0438 388536 www te...

Страница 2: ...ires separately The earth wires must be fixed by means of an additional fastening nearby the terminals this fastening has to be done by qualified technical personnel during the installation phase The...

Страница 3: ...ac MOTOR L1 L2 L3 L1 Rain alarm ON L2 wind alarm flashing L3 Not used TRANSFORMER Rain Sensor Wind Sensor Wired input LED OUTPUT SIGNAL 15 MOTOR OPEN 16 MOTOR CLOSE 17 MOTOR COMMON 18 NEUTRAL 230Vac 1...

Страница 4: ...ening STOP CH5 Opening CH6 STOP CH7 Closing 7 channels transmitter 3 channels transmitter 2 channels transmitter CH1 Opening STOP CH2 Closing STOP CH3 Opening STOP CH4 Closing STOP CH5 Opening CH6 STO...

Страница 5: ...annel transmitter in which every channel is connected to a single operation P1 1 sec 9 TIMES last CH1 100 CH2 75 CH3 50 CH4 25 CH5 DIM CH6 DIM CH7 OFF Press 9 times P1 keeping pressed the ninth time T...

Страница 6: ...ts a continuous sound Press the button to delete within 10 seconds Once the memorization is successfully completed the buzzer emits a fast intermittent sound P1 1 sec 5 TIMES last within 10 sec 5 1 Re...

Страница 7: ...ary only for the application PERGOLA The procedure below will be applied just in case the DIP4 is set to OFF ON 1 2 3 Move DIP3 to ON The buzzer makes a beep The functioning mode automatically switche...

Страница 8: ...cover Thermoplastic ABS Colour of the box and its cover Grey RAL 7035 Cable glands M16 POLIAMMIDE 6 6 Sealing ring of cable glands NEOPRENE Self extinguishing class V2 UL 94 Not suitable for direct UV...

Отзывы: