3
M1
M2
1
Connections, adjustments and control unit warnings
1 +24V
POWER SUPPLY
2 POWER SUPPLY GND
3 MOTOR 1 (OPEN)
4 MOTOR 1 (CLOSE)
5 MOTOR 2 (OPEN)
6 MOTOR 2 (CLOSE)
7 WIND SENSOR (BROWN)
8 WIND SENSOR (BLUE)
9 RAIN SENSOR (WHITE, +12V
)
10 RAIN SENSOR (BLUE, SIGNAL)
11 RAIN SENSOR (YELLOW, GND)
12 AERIAL RF
13 AERIAL GND
14 TEMPERATURE SENSOR (BLACK)
15 TEMPERATURE SENSOR (WHITE)
LED COLOUR STATUS
MEANING
L1
RED
ON
until next manoeuvre
MOTOR 1: Limit switch or alarm
L2
RED
ON
until next manoeuvre
MOTOR 2: Limit switch or alarm
L3
BLUE
ON
Synchronized mode activated
One
flash every second
Synchronized mode activated (
during configuration
)
One
flash every 2 s
Independent mode activated (
during configuration
)
L4
RED
One
flash every 10 s
Water draining alarm (par.
4.4
)
Two
quick flashes every 10 s
Rain alarm (par.
4.4
)
Three
quick flashes every 10 s
Ice / Snow alarm (par.
4.2 - 4.3
)
Four
quick flashes every 10 s
Wind alarm (par.
4.1
)
Five
quick flashes
Unexpected absorption of one motor in synchronized mode
Six
quick flashes
Built-in motor limit switch activated
Seven
quick flashes
Motor stopped by current absorption over the threshold
Eight
quick flashes
Safety limit switch
Ten
quick flashes
One motor is short-circuited
One
flash every 2 s
Rain sensor is deactivated
One
flash every 3 s
Temperature sensor is deactivated
L5
RED
ON
Power ON
Optional LED CARD
(only in TVPLA868CC2(S) version)
Memory
10A Fuse
24V
Power supply
-
+
RAIN
sensor
WIND
sensor
Aerial
TEMP.
Sensor
ATTENTION!
The electronic board is protected by a
10A
fuse.
The maximum allowed power, including the plug-in LED controller board, is
240W
.
= Weather sensor alarms
= MOTOR alarms
FIRST POWER ON:
at first power-on, the system is
waiting to be programmed with the memorization of
at least one transmitter (par.
3
) and the configuration
of the motors and relative working time (see below).
MOTOR CONFIGURATION:
Identify the correct
product application from the 3 given below and follow
the relative configuration procedure.
Attention
: if
the wrong application is selected, the configuration
procedure must be repeated for the correct application.
= It takes effect
DURING
configuration
DIP
MEANING
1 - 2 - 3
Setting of wind sensor threshold (see par.
4.1
)
4 - 5
Motor control mode (see pages
4…7
)
6
Maximum motor current threshold set during configuration
(see par.
2.4
)
2
1
6
5
4
3
14
15
13
12
P1 P2
L5
DIP switch
8
7
11
10
9
L3
L2
L1
L4
Not
used