Sequence

Meaning

Solution

1 costant beep (continuous or 
intermittent)

Faulty control unit

Replace the control unit

2 beeps

Motor problem

- Set the limit switches
- The thermal protection could be activated. Wait while the motor cools down.
- Check the motor connection
- Test the motor separately by means of a proper tool

3 beeps at startup

Radio receiver is empty

Memorize at least one transmitter

3 beeps (L1 = ON)

Safety test failure: photocells (FTC input)

Check photocells alignment and the connections

4 beeps

Radio receiver is full

Max. number of transmitter exceeded

5 beeps (L2 = ON)

Safety test failure: wired safety edge

- Check the rubber profile general condition
- Check photocells alignment and the connections

5 beeps
(see also      led on the front 
cover)

Safety test failure: wireless safety edge system

Control unit checks

- The radio card (master) must be correctly inserted in the plug: check all the pins
- The radio card (master) must be paired with the bottom slat transmitter (slave)

Bottom slat transmitter checks

- Check type, polarity and charge level of the batteries
- Check functionality by pressing the button
- Check the DIP1 position (at par. 2.5)
- Check wiring between bottom slat transmitter and sensitive edge (terminals and wire colour)

Sensitive edge checks

- Check the rubber profile general condition
- Check the functionality by means of the testing procedure with DIP2 (at par. 2.5)

5 quick beeps every 5 seconds Low batteries in the bottom slat transmitter

Replace the batteries as soon as possible. Pay attention to the polarity.

6 beeps (L3 = ON)

Safety test failure: emergency STOP (TB)

Check the safety device connected and the connections

8 beeps

Limit switch error: the manoeuvre exceeded the working 
time.

Check the limit switches and, in case, set them again

9/10 beeps

One of the relay is defective (see the diagram at par 2.2) Replace the control unit

Acoustic signals from the control unit

 TROUBLESHOOTING (WHAT TO DO IF...)

 

   

8

Other possible issues

Problem

Solution

None of the previous signals, but the door doesn’t move downward

Command an opening manoeuvre until the top limit has reached.

In the closure, the door hits the floor and opens again

- The bottom limit could be too low, adjust it upwards
- In case of uneven floor use the procedure 3.4 to deactivate the safety edge in the last part of the closure. It 
is necessary to command the closure starting from the upper limit switch in order to be effective

The door can be operated but the safety systems don’t activate

Check the motor direction. If wrong, swap brown and black motor wires over (terminals 5 & 7)

The control units responds to the commands sent by transmitters, but the 
front cover is not functioning

- Check if the connection flat cable is correctly inserted in the board plug
- If the      led flashes, the “holiday mode” is activated

The fuse blows while operating the door

Check again the wirings

Содержание TVNRG868E04

Страница 1: ...Product TVNRG868E04 Doc T928 01_EN Date 02 09 2021 Control system for garage doors Installer s instruction manual...

Страница 2: ...tomatic opening hold to run closing and automatic Automatic closing with programmable pause time Exclusion of the safety edge in the last part of the closure in case of bumpy floor Motor torque contro...

Страница 3: ...itter 4 Safety edge wireless transmitter Complete installation 1 NRG control unit 2 Tubular motor 240Vac 3 Hand transmitter 4 Safety edge wireless transmitte 5 Wireless security keypad 6 Wired photoce...

Страница 4: ...ge terminals ON transmission error or drained batteries 3 3 15A fuse L2 ON activated safety alarm transmission error or drained batteries 4 Aerial connection OFF normal functioning 5 Programming comma...

Страница 5: ...Wired infrared 8K2 safety edge Emergency STOP TB Push button TD Wired photocells TB COM COM TD Da stampare a colori CONNECTION 12 Photocells power supply 12Vdc 13 Safety common COM 14 Photocells powe...

Страница 6: ...connect a 8K2 resistor between terminals 16 and 17 Reflex photocell Pair of standard photocells N C If no photocells are used terminals 14 and 15 must be closed by a jumper NO WIRED SAFETY DEVICE CONN...

Страница 7: ...its movement The system performs an auto test before any movement RADIO CARD MASTER 1 BK 2 2 3 4 5 6 BK 2 1 2 1 BK 2 2 BK 2 1 BK 2 2 3 4 5 6 BK 2 1 2 1 1 2 1 BK 2 2 3 4 5 6 BK 2 1 2 1 BK 2 2 3 4 5 6...

Страница 8: ...2 1 B K 2 2 3 4 5 6 B K 2 Green Brown White 1 3 1 B K 2 2 3 4 5 6 B K 2 Green Brown White 2 a b B1 B2 3 4 5 6 BK2 1 2 B1 B2 3 4 5 6 BK2 1 2 a b 1 B K 2 2 3 4 5 6 B K 2 Green Brow n White 1 2 1 B K 2 2...

Страница 9: ...ssed the command button for more than 5 seconds The control unit will automatically switch to hold to run mode PRELIMINARY CHECK AND INITIAL START UP 3 HOLD TO RUN L4 FLASH FAST Open the door in hold...

Страница 10: ...ation L1 will costantly flash and L2 led off MATCHING OF THE WIRELESS SAFETY DEVICE SYSTEM ACTIVATION DEACTIVATION 3 2 DEACTIVATION 30 SECONDS TIMEOUT X1 Switch the unit on Move DIP1 from ON to OFF po...

Страница 11: ...N 30 SECONDS TIMEOUT X10 Within 30s from power ON Press P1 button 10 times and keep it pressed for 5s The buzzer emits 3 beep ON P1 5 s keep it pressed for 5s 1 Open the door completely by means of a...

Страница 12: ...OP CLOSE STOP OPEN STOP CLOSE CH1 CH2 CH3 CH4 CH5 CH6 CH7 OPEN STOP CLOSE OPEN STOP CLOSE OPEN STOP CLOSE OPEN STOP CLOSE OPEN STOP CLOSE OPEN STOP CLOSE OPEN STOP CLOSE TYPE D for MOTOR LIGHT TYPE B...

Страница 13: ...ne press to another one TYPE OF MEMORIZATION P1 A Open Stop Close x1 Press the button of the transmitter relative to the code to memorize B Open Stop Close Stop x2 C Light On Light Off x3 D Open Close...

Страница 14: ...t sound O N 2 1 DIP1 DIP2 Sensitivity Off Off High On Off Medium Off On Low On On Extra low TVSSH868A01 The garage door must be completly close Only for TVSSH868A01 NOTE It is not necessary if you use...

Страница 15: ...sound Press the button of a transmitter already memorized The buzzer stops for 1s The buzzer emits a continuous sound Press the button of a new transmitter to memorize with the same functions The buzz...

Страница 16: ...ter to delete Once the deletion is successfully completed the buzzer emits a continuous sound TYPE OF DELETION P2 SINGLE RADIO CODE x4 Press the button of the transmitter relative to the code to memor...

Страница 17: ...enabled The default time is 30 seconds It is possible to set the time from 5 seconds to 180 seconds 30 seconds timeout 5 seconds timeout Press P3 button of a memorized transmitter and hold it for 5s...

Страница 18: ...ttons Note when the mode is activated wireless and wired input commands are still enabled ACTIVATION DEACTIVATION 10 seconds timeout Press the STOP button in the front cover and keep it pressed for 10...

Страница 19: ...means of the testing procedure with DIP2 at par 2 5 5 quick beeps every 5 seconds Low batteries in the bottom slat transmitter Replace the batteries as soon as possible Pay attention to the polarity...

Страница 20: ...es could occur failure to follow instructions can cause personal injury and or property damage The correct functioning of the product must be checked once a year Keep the 240Vac wires separately from...

Отзывы: