Teleco TVDMM868A05 Скачать руководство пользователя страница 10

10

a. The 4/7/42 channel transmitter is associated to more than one output. No other input available.

4- Hold down 

CH4 or CH7

 button for 5 

sec. At the end only the load connected 

to the selected output will turn on at the 

new value.

1- Press the button relative to the scene to modify. 

All the output associated to this transmitter will 

turn the load on at the preset value.

2- Press 

P4

 to select the output to modify 

(the selection will be indicated by the 

relative led ON). 

ATTENTION: 

the next 

steps must to be executed within 60 

seconds!

3- 

Adjust

 the new value:

• 

keeping P1 pressed to Dim UP/DOWN

•  (

4ch.

 transmitters) keeping the button relative to the 

scene to modify pressed to Dim UP/DOWN

•  (

7/42ch

. transmitters) use the buttons CH5, CH6 to 

Dim UP/DOWN

 Only the selected output will change its intensity.

Press P4

 

to select the output

OR

Press

Adjust

Adjust

Keep pressed 

to DIM

5 sec. press

5 sec. press

b. The 4/7/42 channel transmitter is associated to more than one output and there are also wired 

safety low voltage input (T5 .. T8) to command the output.

2- Adjust the new value with the wired 

button connected to the output to modify 

(T5 = OUT1, T6 = OUT2, T7 = OUT3, 

T8 = OUT4).

Note: 

It’s not possible to use the high voltage input for this procedure. 

Keep pressed 

to DIM

1- Press the button relative 

to the scene to modify. All 

the output associated to this 

transmitter will turn the load 

on at the preset value.

Press

3- Hold down 

CH4 or CH7

 

button for 5 sec. At the end 

only the load connected to the 

selected output will turn on at 

the new value.

5 sec. press

5 sec. press

CH1
CH2

CH3

CH4

CH7

CH1
CH2

CH3

CH4

7/42 CH.

4 CH.

T5   T6   T7   T8

CH7

CH1
CH2

CH3

CH4

7/42 CH.

4 CH.

CH5
CH6

CH1
CH2

CH3

CH4

7/42 CH.

4 CH.

CH1
CH2

CH3

CH4

Содержание TVDMM868A05

Страница 1: ...utput Maximum power each output 230Vac 50 60Hz 110Vac 50 60Hz 25W R 25VA L C 7W Led 12W R 12VA L C 4W Led 500W R 500VA L C 100W Led 250W R 250VA L C 50W Led Characteristics Suitable for any type of lo...

Страница 2: ...7 GND for L3 8 GND for L4 M3 9 10 Load L1 11 12 wired input T1 M4 13 14 Load L2 15 16 wired input T2 M5 17 18 Load L3 19 20 wired input T3 M6 21 22 Load L4 23 24 wired input T4 T1 T2 T3 T4 ON OFF and...

Страница 3: ...TTING DIP Output 1 2 3 4 see p 4 P1 ON OFF Dim P2 memorize TX P3 delete TX P4 output selection SELECTED OUTPUT Output 1 2 3 4 ON output selected by means of P4 button or associated to the received rad...

Страница 4: ...ying perform the procedure of fine adjustment see par 3 3 page 13 keeping the dip switch configuration as it is In case of a later modification of the load type it might be necessary adjusting the min...

Страница 5: ...he button P4 the selection will be indicated by the relative led ON 1 2 Memorization of one transmitter button with On Off Dim function With short impulses turn the load on and off keeping it pressed...

Страница 6: ...by the relative led ON 2 Press the button P2 four times and hold it down the fourth one the buzzer will make a beep each time and then sounds continuously 3 During the beep sound press the button of...

Страница 7: ...he button P4 the selection will be indicated by the relative led ON 2 Press the button P2 seven times and hold it down the seventh one the buzzer will make a beep each time and then sounds continuousl...

Страница 8: ...TS the 2 channels of TVTXSxx and TVTXLR02x can be assigned to the preset values of activation 100 recognized movement 66 NO movement which are CH1 and CH2 of a 7 channel transmitter see the procedure...

Страница 9: ...t and each of them must have different values of intensity when a preset scene is commanded it is necessary to clearly identify the output which relative preset will be modified This is possible in di...

Страница 10: ...the selected output will change its intensity Press P4 to select the output OR Press Adjust Adjust Keep pressed to DIM 5 sec press 5 sec press b The 4 7 42 channel transmitter is associated to more th...

Страница 11: ...nual The new transmitter will have the same functions of the transmitter used for its memorization Press P3 Press Press c The 4 7 42 channel transmitter is associated to more than one output as MASTER...

Страница 12: ...y 1 Clean the output selection using P4 Output LED must be all OFF 2 Press the button P3 two times and hold it down for 10 sec the buzzer will make one beep and then sound quickly and intermittently 3...

Страница 13: ...hold them down Press P4 to select the output Press P4 to select the output Press P1 P2 P3 once and hold them down Press P4 to select the output 1 Select the output using P4 2 Press P1 P3 and hold the...

Страница 14: ...e reports roughly the resistance values and the maximum current of a copper wire according to its length Section mm2 R ohm Km Max current A 1 19 5 5 1 5 13 3 10 2 5 7 98 16 WARNING If any cable is dam...

Страница 15: ...utput Power 2000W 500W for each output at 230Vac 1000W 250W for each output at 110Vac Reception frequency 868 3 MHz TVDMM868A05 916 MHz TVDMM916A05 Operating temperature range 20 45 C The maximum numb...

Страница 16: ......

Отзывы: