6
7.1 - TECHNICAL SPECIFICATION
-
Power
supply 230Vac
- Operating temperature range
-20 / +50 (°C)
-
Protection
rating
IP20
- Max. power on relay
10A
-
Telephonic
module
SIM900
QBand
-
SIM
type
Standard
7.2 - SAFETY INFORMATION
The product at issue must be installed only by qualified technical personnel respecting the laws concerning
the electrical installations. All the connections must be rated for a single-phase 230Vac power supply. For the
disconnection from the power line, use an all-pole switch with contacts having a dimension of at least 3,5mm.
Only suitable materials for the connections must be used to guarantee insulation that complies with current
standards on the subject of electrical safety. The receiver only carries out ON/OFF commands and all safety
devices required by the system must be arranged separately.
The functioning of the device next to radio, televisions, mobile phones or any other electronic devices, could generate
interference. The device can be subject to external interferences, which can influence its proper functioning.
Do not install the device next to pacemakers or any other electronic medical devices, because it could interfere
with the correct functioning of these devices. We inform that GSMxxx works using radio frequency and not one
telephonic company can guarantee the connection to the device at any moment. For this reason the product
cannot be used with personal emergency systems.
Furthermore the user is totally and exclusively responsible of the remote command of the door by means of the
product GSMxxx. Teleco Automation Srl declines any responsibility for direct or indirect damages caused by
possible malfunctioning, wrong installation or external causes like power supply black-out or GSM signal missing.
Notes:
- A telephone number cannot be memorized more than one time.
- In order to delete a telephone number by means of the command “
password,DAC,xxxxxxxx
”, it is necessary
to write it with the same dialing code earlier used for the command “
password,MAC,xxxxxxxx
”.
Hereby Teleco automation s.r.l. declares that the product complies with the essential requirements and other
relevant provisions, established by the Directive 1999/5/EC. The declaration of conformity can be consulted on
the web site:
www.telecoautomation.com/ce
.
In the view of a constant development of their products, the manufacturer reserves the right for
changing technical data and features without prior notice.