14
6.1 Auto close time setting
This procedure configures the time lapse between complete opening and the automatic closure (if enabled).
The default time is
5 seconds
. It is possible to set the time from 5 seconds to 90 seconds.
Note:
The procedure can be executed only
within 30 seconds from power on
.
The control unit will add by default 5 seconds to the time measured in the procedure.
Press the internal
P3
button of a memorized transmitter and keep it pressed for
5 seconds
. The buzzer will emit one beep.
Release and press it again
eight times
within 5 seconds
. The buzzer will make
two
beeps at the end.
In case of time-out, the control unit will sound four beeps and exit the procedure automatically.
Press once
P3
to start the counting of time. The buzzer will make one beep.
Press again
P3
to stop the counting after the desired lapse. The value will be memorized by the control unit.
START
STOP
6.2 Courtesy light time setting
This procedure configures the time of activation of the courtesy light.
The default time is
60 seconds
. It is possible to set the time from 60 seconds to 12 hours.
Note:
The procedure can be executed only
within 30 seconds from power on
.
The control unit will add by default 60 seconds to the time measured in the procedure.
within 5 sec.
8
times
keep it pressed
( 5 s)
START
STOP
P3 button is
located inside
the transmitter.
within 5 sec.
5
times
keep it pressed
( 5 s)
Press the internal
P3
button of a memorized transmitter and keep it pressed for
5 seconds
. The buzzer will emit one beep.
Release and press it again
five times
within 5 seconds
. The buzzer will make
three
beeps at the end.
In case of time-out, the control unit will sound four beeps and exit the procedure automatically.
Press once
P3
to start the counting of time. The buzzer will make one beep.
Press again
P3
to stop the counting after the desired lapse. The value will be memorized by the control unit.
P3 button is
located inside
the transmitter.
P3
memorized
P3
memorized
P3
memorized
P3
memorized
P3
memorized
P3
memorized
P3
memorized
P3
memorized