GHN-AT-PROG-UPLC-3-SLOPE Reference Manual
Page 12 of 12
6.2.2
Status Messages
•
BUSY: Settings are being saved.
SUCCESS: Settings successfully saved
READY: Ready to configure
FAIL: Failed to save settings
Страница 1: ...Model GHN AT PROG UPLC 3 SLOPE PLC 3 Channel Attenuator with Slope Filter CLI and GUI Reference Guide Rev Date of Publication 04 30 2019 Results You Can Count On...
Страница 2: ...C 3 Channel Attenuator with Slope Filter These applications are used to set and read the attenuation levels and slope filter of the attenuation device Contact Information Telephone E mail Internet Gen...
Страница 3: ...E to be defective in material or workmanship during the warranty period Warranty repairs will be performed at the point of manufacture Equipment approved for return for warranty service shall be retur...
Страница 4: ...will have a 90 day warranty In those cases where no trouble is found a reduced charge will be billed to cover handling testing and packaging Whether in or out of warranty a Return Material Authorizati...
Страница 5: ...Begin 2 5 0 Application Installation Steps 3 5 1 Command Line Interface CLI 3 Graphical User Interface CLI 6 6 0 Control 7 6 1 CLI Overview 7 6 1 1 CLI Commands 7 6 1 1 1 Screen Examples 7 6 1 1 2 CL...
Страница 6: ...the facility earth ground 2 0 System Requirements Windows 7 10 Net Framework 3 5 USB 2 0 Cable A Male to Mini B Male 3 0 Specifications Number of Channels 3 Frequency Range 1 to 100 MHz Attenuation R...
Страница 7: ...ces All devices to be controlled must be connected to USB ports in the host PC referred to as the system Each device is identified with a serial number by default This ID number can be changed to a cu...
Страница 8: ...GUI and CLI application prompts for the installation of the required files if they are not found 5 1 Command Line Interface CLI To install the CLI setup program click on Telebyte GHN AT PROG CLI Setu...
Страница 9: ...GHN AT PROG UPLC 3 SLOPE Reference Manual Page 4 of 12 Click Install When the installation is done the Completion screen is shown Click Finish...
Страница 10: ...GHN AT PROG UPLC 3 SLOPE Reference Manual Page 5 of 12 Windows will require Net Framework 3 5 to be installed only if the requried files are not found Click on Download and install this feature...
Страница 11: ...3 SLOPE Reference Manual Page 6 of 12 5 2 Graphical User Interface CLI To install the GUI program click on Telebyte GHN AT PROG GUI Setup 1 3 0 and follow the same procedure as explained in of CLI Ins...
Страница 12: ...set the attenuation and slope filter values on each device All devices must be connected to the system When the user connects any Telebyte device to the system the Refresh command is used to update t...
Страница 13: ...mand Examples Show attndevicelist displays all devices connected to the system along with User ID Number and Device Index Set Command Example Set attn sets the attenuation level of a specified channel...
Страница 14: ...e set userid 87654321 87654 4 show attn UserIDNum Display the attenuation level of the specified devices s connected to the host PC Example show attn 1234567a 1234567b 5 show attndevicelist Display a...
Страница 15: ...nels NOTE Multiple sessions of the GUI and or CLI utilities are not allowed 6 2 1 GUI Screen Examples All active devices connected to the system display a Device on the top of the device panel All oth...
Страница 16: ...OPE Reference Manual Page 11 of 12 To change the User ID for a device click the Edit icon in the upper right corner of the device panel The Enter new user ID dialogue box is shown Enter the new User I...
Страница 17: ...GHN AT PROG UPLC 3 SLOPE Reference Manual Page 12 of 12 6 2 2 Status Messages BUSY Settings are being saved SUCCESS Settings successfully saved READY Ready to configure FAIL Failed to save settings...