Model 458-SM-2-16 Transparent Switching Module
Page 12 of 14
6.3 Example
Commands
The below examples are for Input Signals 1-16 and Output Channels 1-2, for the Module in location/slot 5 of the
enclosure. Each example is dependent on the prior example selection state. A table is displayed that shows the same
examples in a different format.
EXAMPLE
STATEMENT
CODE/RESPONSE
Example 1
Read the Input Signal number that is at Output Channel 2, of the Module in slot 5
RC:05:2
Response is: Input Signal is (0) reset/inactive and terminated.
05:2:0
Example 2
Set Input Signal 3 to Output Channel 1, at the Module in slot 5.
SC:05:1:3
Response
is:
command
completed.
*
Note: Valid as Output Channel 2 of Ex 1 is inactive.
Example 3
Set Input Signal 6 to Output Channel 2, at the Module in slot 5.
SC:05:2:6
Response
is:
invalid.
? [###] Invalid Connection
Note: Input Signal 6 cannot be selected by Output Channel 2 as the Module is in Mode 1.
Example 4
Set Input Signal 10 to Output Channel 2, at the Module in slot 5.
SC:05:2:10
Response
is:
command
completed.
*
Note: Output Channel 1 connection is unchanged. The Module is in Mode 3
with both Output Channel 1 and 2 active.
Example 5
Set Module in slot 5, Output Channel 1, to 0.
SC:05:1:0
Response
is:
command
completed.
*
Note: Output Channel 2 is unchanged. Output Channel 1 is terminated
in 100 ohms and Input Signal 3 is terminated in 100 ohms.
Example 6
Terminate all Input Signals/all Output Channels of the Module
SC:05:A:0
in
slot
5.
Response
is:
command
completed.
*
Note:
All 16 Input Signals and 2 Output Channels of the Module are set to
a 100-ohm termination.
Examples Shown Above, in Table Format
Command
Slot
(1-3 or 1-16)
(2 Digits)
Output Channel
(1-2 or A for ALL)
(1 Digit)
Input Signal
(1-16 or 0)
(1 or 2 Digits)
RC 05 2
SC 05 1
3
SC 05 2
6
SC 05 2
10
SC 05 1
0
SC 05 A
0