background image

Warranty

Included With Your Purchase 

One-year Warranty

 

• 

Telebyte will furnish parts and labor for the repair or replacement of products found by Telebyte to be defective 

in material or workmanship during the warranty period.1 
 

One-year Calibration (where applicable)

 

• 

One N.I.S.T traceable calibrations, one on the first-year anniversary of the product ship date.2 

• 

Calibration report to ensure traceability. 

Extended Customer Care 

There are two options available. Our three-year extended warranty extends the original warranty by an additional 36 
months and the three-year calibration contract provides 36 additional months of calibration.

 

Three-Year Extended Warranty

 

You can extend the original one-year warranty that 
comes with your product by purchasing the 

Three-Year 

Extended Warranty

.3  

Features: 

·

 

Telebyte will furnish parts and labor for the repair or 
replacement of products found by Telebyte to be 
defective in material or workmanship during the 

warranty period.1 

Three-Year Calibration Contract (where applicable)

 

Extended calibration is available through the 

Three-Year 

Calibration Contract

.4  

Features: 

·

 

Yearly N.I.S.T traceable calibrations, each on the 

second, third, and fourth anniversary of the ship date.2 

·

 

Report to ensure traceability. 

·

 

Automatic notification when calibration of your product is 
due. 

Disclaimer of Warranties and Other Terms and Conditions 

1 TELEBYTE, INC. warrants its broadband simulation equipment to be free from defects in material and workmanship, under normal and proper use 
and in its unmodified condition, for 12-months, starting on the date it is delivered for use. TELEBYTE’S sole obligation under this warranty shall be to 
furnish parts and labor for the repair or replacement of products found by TELEBYTE to be defective in material or workmanship during the warranty 
period. Warranty repairs will be performed at the point of manufacture. Equipment approved for return for warranty service shall be returned F.O.B. 
TELEBYTE factory and will be redelivered by TELEBYTE freight prepaid, except for non-continental U.S.A. locations. These deliveries will be sent 
COD freight and import/export charges.  

2 The customer is responsible for freight and customs charges when shipping products to and from Telebyte for calibration services. 

3 You must purchase the extended warranty at the time of purchase or during the initial warranty period. 

4 You must purchase the calibration contract at the time of purchase or during the initial warranty period. 

The above warranty is in lieu of all other warranties, expressed or implied, statutory or otherwise, including any implied warranty of merchantability or 
fitness for a particular purpose. TELEBYTE shall not be liable for any damages sustained by reseller or any other party arising from or relating to any 
equipment failure, including but not limited to consequential damages, nor shall TELEBYTE have any liability for delays in replacement or repair of 
equipment.

 

 

 

Содержание 458-2SL

Страница 1: ...Results You Can Count On Model 458 2SL Multi Channel Local Loop Simulator 0315 0333 Rev D Date of Publication 02 27 06...

Страница 2: ...58 Line Modules it becomes a two channel local loop simulator The built in Control Module interfaces with a PC or terminal via IEEE 488 or RS 232 to control loop length settings or it can be used as a...

Страница 3: ...ELEBYTE INC warrants its broadband simulation equipment to be free from defects in material and workmanship under normal and proper use and in its unmodified condition for 12 months starting on the da...

Страница 4: ...cases where no trouble is found a reduced charge will be billed to cover handling testing and packaging Whether in or out of warranty a Return Material Authorization number RMA is required and may be...

Страница 5: ...ations 2 3 0 Connections 3 4 0 RS 232 Control 4 Connections 4 User Command Interface 5 Serial RS 232 Mode Command List 5 5 0 IEEE Controls 8 Connections 8 User Command Interface 8 IEEE Mode Command Li...

Страница 6: ...ndard 19 in rack and accepts a maximum of two Line Modules The built in Control Module is used to configure a Line Module to a particular length via the IEEE 488 or RS 232 port When configured for IEE...

Страница 7: ...19 in W x 22 in D x 3 47 in H 482 6 mm W x 558 8 mm D x 88 1 mm H Environmental Operating temperature 0 to 50 degrees C humidity 0 to 95 relative humidity non condensing Remote Control Connectors RS...

Страница 8: ...f each RJ 45 are supported Refer to Figure 1 for the configuration of the RJ 45 jack L L L L L Do not exceed the maximum ratings as listed in section 2 0 Specifications For best accuracy the I O cable...

Страница 9: ...2 on the Model 458 2SL connects to the RECEIVED DATA pin in the Communications Port Connector on the PC or controller Pin 3 on the Model 458 2SL connects to the TRANSMIT DATA pin in the Communication...

Страница 10: ...length CC 02 458 2SL CC 16 458 B sl aa bb xxxx Set cards aa bb length to xxxx aa bb card no in range of aa to bb set to length of xxxx sl aa bb xxxx Set cards aa bb length to xxxx aa bb two cards joi...

Страница 11: ...a Read serial no of card aa read sn of card aa read sn of control module aa 00 rs aa bb Read serial no of card aa bb read sn of cards in the range of aa to bb rs all Read serial no of all cards read s...

Страница 12: ...display ed Echo disable inputs not echoed and format output for user control program ts aa r Test single segment turn on single segment of card aa r a f h Help RS232 command list read RS232 command l...

Страница 13: ...E 24 pin Connector Connect a standard IEEE cable from the Model 458 2SL to the IEEE General Purpose Interface Bus controller User Command Interface The Model 458 2SL is intended to be operated from an...

Страница 14: ...oined for a total length of xxxx setcard length all xxxx Set all cards length to xxxx cards 01 to 16 set to length of xxxx length english Length I O in English units length xxxx in feet or K feet leng...

Страница 15: ...anual disable Disable manual control disable manual setting of lengths or configuration manual enable Enable manual control enable manual setting of lengths or configuration readcard sn all Read seria...

Страница 16: ...et card lengths English Metric mode and Echo enable disable are maintained during power off in both RS 232 and IEEE modes Manual control is enabled at power on Page 11 SRExx Enables Status Bits as def...

Страница 17: ...orted 4 16 1 Enable Message Available bit MAV 5 32 1 Enable Event Status Bit ESB 6 64 1 MSS this bit is always enabled 7 128 0 Not Supported Event Status Enable Register Bit Value Set Operation 0 1 1...

Страница 18: ...on line The inductance L and capacitance C are the reactive components of the line These elements are not lumped but are distributed over the entire length of the line Therefore a theoretical equivale...

Страница 19: ...ical since the characteristic impedance varies with frequency Use of 100 for terminating wire lines operating in this frequency range has become standard practice in the industry Measurements must alw...

Отзывы: