![TeleAdapt RoomCast TA2400 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/teleadapt/roomcast-ta2400/roomcast-ta2400_installation-and-configuration-manual_1079689015.webp)
TeleAdapt Roomcast
Installation Guide
Setup Wizard and Cloning
This feature is available in Roomcast software release 4.10 and above only. For earlier software revisions
con
fi
guration is via the
Admin Mode
interface, see the following section for further details.
The Roomcast Setup Wizard is designed to minimise the time taken to install Roomcast. The Setup Wizard
runs only once, on initial startup.
You will be prompted for a system ID. If you have not been given a system ID then use the default which is
“999998”. If you have been given a system ID then you should also have a PIN code, you will need to enter
both system ID and PIN to proceed.
The Setup Wizard steps through the key con
fi
guration parameters for Roomcast. In a typical installation
many of these parameters will be constant across multiple units, these parameters can be pre-de
fi
ned in a
clone
fi
le called “RC_Con
fi
guration.json” which is placed on a USB drive that the setup wizard reads. Setup
Wizard only prompts for parameters not speci
fi
ed in the “RC_Con
fi
guration.json”
fi
le.
Before the Setup Wizard applies any changes it will show a summary con
fi
guration and ask for
con
fi
rmation. The settings are then applied and Roomcast will display the initial Guest UI.
Clone
fi
le - RC_Con
fi
guration.json
To simplify generation of the RC_Con
fi
guration.json clone
fi
le, use a web browser and enter the URL http://
rc.teleadapt.com/custom/con
fi
g. Set the default values you require using the web form, any parameters you
leave unspeci
fi
ed will be omitted from the generated
fi
le and the Setup Wizard will prompt you for missing
settings when it runs. Use of RC_Con
fi
guration.json is not mandatory, however it is recommended to use it
to set parameters that are constant across a large number of rooms.
If for any reason you need to manually edit the RC_Con
fi
guration.json
fi
le then you must use a plain text
editor like UltraEdit, BBEdit or Atom. Using a rich text editor or word processing software will corrupt the
fi
le.
The name/value pairs used in RC_Con
fi
guration.json are also case sensitive and only certain well de
fi
ned
values are allowed. For this reason the web tool is recommended.
An example RC_Con
fi
guration.json
fi
le is shown below:
{
"time_zone":"Chicago",
"topology":"in_room_pan",
"wan_ip_assign":"dynamic",
"auto_update":"enabled",
"auto_update_time": "23:00",
"room_prefix":"RM",
"idle_timeout":"3mins",
"checkout_time":"13:00",
"method":"HDMI-CEC"
}
Contact TeleAdapt for further information.
Revision 2.1 -
May 2018