Installation instructions
│
R2
│
Annex A: Implementation Specifications – Lynx (in
English)
Bit
Contents
7–0
Radio Channel (11-29) (Default: 17)
15–8
Reserved
A .2 .5 F UN C T I O N A L I T Y – 0 X0 0 0 6
Bit
Contents
0 (LED Control)
0 = Respond To Event handles LEDs for specific units (Default)
1 = LED state registers controls LEDs for all units
1 (Listen Mode)
00 = Only events from learned units are stored on the event queue (Default)
01 = Events from all units (with this stationary as recipient) are stored on the
event queue.
10 = Promiscious mode. Unit stores all events on the queue regardless if the unit
is recipient or if there are broadcast packets. Mainly used for testing purposes.
11 = Reserved for future use
2 (Listen Mode)
3 (Only 1 TX)
0 = Max number of transmitters is 16 (Default)
1 = Max number of transmitters is 1
15-4
Reserved
A .2 .6 RS 2 3 2 B A UD RA T E – 0 X0 0 0 7
Value
Baudrate
0 (default)
19200 baud
1
9600 baud
2
38400 baud
3
57600 baud
A .2 .7 RS 2 3 2 S ERI A L PO RT MO DE – 0 X0 0 0 8
Value
Baudrate
0 (default)
8 bits, Even parity, 1 stop bit
1
8 bits, Odd parity, 1 stop bit
2
8 bits, No parity, 2 stop bits
3
8 bits, No parity, 1 stop bit
A .2 .8 RS 48 5 B A UD RA T E – 0 X0 0 0 9
Value
Baudrate
0 (default)
19200 baud
1
9600 baud
2
38400 baud
IM-LX-RX101-EN-v01
31