Installation instructions
│
R2
│
Annex A: Implementation Specifications – Lynx (in
English)
Address
Contents
0x0004
RS485 Modbus address (default 0x66 )
0x0005
Radio channel (default 17)
0x0006
Functionality
0x0007
RS232 Baud rate
0x0008
RS232 Serial port mode
0x0009
RS485 Baud rate
0x000A
RS485 Serial port mode
0x0200
Transmitter button state (bit mapped)
0x0201
Discrete inputs on stationary unit (bit mapped)
0x0600
Sampled Input Power on stationary unit.
0x0A00
LED2 state (Only lower byte used)
0x0A01
LED3 state (Only lower byte used)
0x0A02
LED4 state (Only lower byte used)
0x0A03
LED5 state (Only lower byte used)
0x1000
Discrete outputs on stationary unit (bit mapped)
A .2 .1 S T A T US REG I S T ER – 0 X0 0 0 0
Bit
Indicates
0
0 = FIFO OK, 1 = FIFO has overflowed, oldest event discarded.
15-1
Reserved
Table: Status register bit mapping
A .2 .2 RES ERV ED – 0 X0 0 0 1 / 0 X0 0 0 2
Reserved for backwards compatibility. Do not write.
A .2 .3 MO DB US A DDRES S – 0 X0 0 0 3 / 0 X0 0 0 4
According to Modbus specification only address 1 to 247 are valid. All unused
values are reserved.
Bit
Contents
7–0
Modbus Address (1-247) (Default: 0x66)
15–8
Reserved
A .2 .4 RA DI O C H A N N EL – 0 X0 0 0 5
According to IEEE802.15.4 only 11 to 26 are valid. All unused values are reserved.
30